23
Automatic Functions
Over-Temperature Protection
To prevent runaway heating of the spa, if the water exceeds 104°F the Filtration Cycles will be
shortened to prevent excess heating of the water by pump 1 (minimum total filtration time per day
will be 2 hours to maintain water cleanliness) until the water temperature decreases to the tem-
perature set point.
Note: That this spa does not incorporate a feature to actively cool the spa water.
Power-Up Sequence
Upon system start-up (turning the power on), the control will flash a few diagnostic numbers
then all pumps will turn on when it enters a filter cycle in which pump 1 will run continually in low
speed. The spa will also begin to evaluate the temperature. If heat is required, the pump will run
on low speed, the heater will be activated, and the heater indicator will be lit. Filter cycles will be
based on the spa start-up time. If the filter cycles occur at an inconvenient time of day or night,
turn off the power and start-up at the desired time.
Smart Winter Mode
The Smart Winter Mode protects against freezing by turning on the pumps several times a
day to prevent water from freezing in the plumbing and/or pumps. The Smart Winter Mode
indicator will be lit when the Smart Winter Mode is on.
Heating
The temperature can be set to a maximum of 104°F and measures water to within ± 1°F. Pump 1
will activate periodically to check the temperature and the spa will heat on demand (it can not ac-
tively cool the water) any time the actual temperature drops 1 degree below the set point. Pump
1 will automatically run in low speed and the heater will activate, as will the heater indicator (it will
flash if the spa calls for heat but the heater has not yet activated).
Note:
That pump 1 may activate on low speed for several minutes before the heater indicator
is lit in order to determine system diagnostics and may run for several minutes after heating to
ensure the heating coil is not damaged.