Ground Fault Circuit Interrupt (GFCI) Wiring Diagram
NOTES:
1. NEUTRAL AND GROUND MUST BE ISOLATED AT THE SUB PANEL.
2. Positions of electrical connections may vary by breaker manufacturer.
3. For specific breaker and wire size refer to page 69.
RED
BLK
GR
WHT
TB1
Sub Panel at Spa
Main Panel
Neutral/Ground Bar
See NOTE 2
GFCI
Breaker
Spa Pac
Terminal block
inside of Pac
Breaker
Neutral Bar
Ground
Green
Ground
Green
* Load Neutral (white) must
connect to the GFCI break-
er at the Sub Panel NOT the
neutral bar
Load Neutral (White)
*
White Pigtail
Wire
Isolated
Ground Bar
Red
Black
Red
Black
Neutral
(White)
Spa Pack Connections
INSIDE THE
CONTROL BOX
Black
Red
White
Green
L1
L2
Gr
N
External Power
GROUNDING LUG
Electrical Set Up