Operating
Instructions
OPERATING INSTRUCTIONS
CAUTION
If the water in the tank is decreasing, the red warning light “Water Shortage” (06E) switches on and the warning
light (11F) on the hand grip blinks, followed by an intermittent signal tone. The power supply to the heating
element is cut off until the water tank (01) is fi lled again.
Fill water in the tank and confi rm by pressing the button (06B).
This device is equipped with a double control system that checks if there is water and thus monitors the liquid in
the refi ll tank as well as in the boiler as follows:
The system checks both the tanks each time the device is switched on, fi rst the boiler and then the refi ll tank. If
the liquid level in the boiler is insuffi cient, the system automatically restores the liquid level in it, in which case the
warning light Water Shortage switches on for the duration of this action (approx. 3 seconds).
If the warning light Water Shortage continues to remain on and is accompanied by an acoustic signal tone, then
it is indicative of a liquid shortage in the tank; the tank must be fi lled.
1
Before using your Thermostar, ensure that the
surface of the appliance does not have any
damage. Check if the volt and ampere ratings of
your power source match the data on the appliance
sticker.
2
Remove the tank cover (1) from the appliance
and fi ll the reservoir with at least 1 liter of water.
You may use straight tap water, distilled or os-
mosis water. Please do not fi ll any chemicals in
your Thermostar.
3
Connect the power cord (03) to an outlet.
4
Connect the steam plug (12) to the designated
appliance accessory outlet (05). Press fi rmly until
the securing button (13) is engaged.
5
Press the main switch (2) at the back of the
appliance, switch (06A) and the steam boiler
button (06B) and wait for approx. 5 minutes until
the indicator light (06D) is illuminated. It indicates that
the boiler has steam. The switches (11A and 11E) on
the handle should be off.
6
When the indicator light (06D) is illuminated, you
can adjust the desired steam fl ow (steam button
11A) as follows:
a. pressed 1x = Minimum steam (11B)
b. pressed 2x = Medium steam (11C)
c. pressed 3x = Maximum steam (11D)
Press the steam button (10) to release steam. The
status is displayed on the control panel (indicator
lights (06C)).
7
Using the button (11E) allows you to add hot
water to the steam.
Press the button only at short intervals (a few se-
conds) to avoid discharging the generator too quickly.
The switch (11E) only functions if the boiler switch
(06B) was also pressed.