VENTILATION 

Perfect ventilation is very important to ensure the cooling system works properly. Heat is generated in the 
cooling system. The heat must be able to escape into the open air. Cold air extraction is necessary to allow 
the cooling system to cool down again and to maintain the circulation of air.  
 

FIGURE   5

: The refrigerator is ventilated by means of two openings in the wall of the caravan or 

motor home across which ventilation gratings are placed. Cold air comes in through the lower 
grating. The cooling system heats the cold air and it takes out again through the upper grating 
(chimney effect).  

4.1 

Installation ventilation gratings 

 

-

 

Install the ventilation gratings exactly as described in this manual. 
Any other method of installation will invalidate the manufacturer’s warranty for the 
refrigerator.   

-

 

Always fit the ventilation gratings at the rear of the refrigerator. 
Fitting them at the side will reduce the refrigerator’s cooling capacity.  

 

FIGURE 6

The lower ventilation grating

  

Make sure the lower ventilation grating is always placed right behind the combustion chamber. This 
grating is also used for maintenance access. In case of models with a wheel  arch recess (N80 / 90 / 
112), the bottom of the lower ventilation grating must be level with the top of the wheel  arch.    
 

There must be a hole in the floor. If a leak occurs, this hole will allow the gas to stream 
outside instead of building up on the floor. A grating is used for this matter with the 
N80/90/112 models. The other models (N100/109/110/145) have a grating which is 
situated above floor level and therefore need an extra hole in the floor, with a diameter in 
conformity with local regulations, but we advice a diameter of  at least Ø40 mm.

 

 

 

FIGURE 7

The upper ventilation grating 

The installation of the upper ventilation grating influences the cooling capacity. The best result is 
achieved when this grating is installed as far above the condenser as possible. Use at least a 110 mm 
distance. Situation [1] is the preferred installation procedure and creates the optimal cooling 
capacity. Situation [2] without a ventilation grating, but with a chimney on the roof, is a possibility. 
Situation [3] is often used, but results in a reduced cooling capacity. 

4.2 

Installation ventilation gratings 

 

FIGURE 8

: A ventilation system compromises of two sets of a vent frame [A], a vent screen [B], 

and a vent outer [C].  To install the ventilation gratings, make, using the templates provided, a 
horizontal rectangular recess in the wall of the caravan or motor home.  
 

1. 

Use the accompanying template to cut out the ventilation recess.    

2. 

Seal the vent frame [A] in a watertight way by means of sealant or butyl tape.   

3.

 

Only for the upper ventilation grating

: assembly the vent cap together with the vent frame 

4. 

Position the vent frame  [A] in place.    

5. 

Place the vent screen [B] in the vent frame. 

6. 

Place the vent outer [C] over the vent frame [A] and fasten it with the two retaining slides.   

 
 
 

5. 

8. 

6. 

7. 

ENG

Summary of Contents for N100

Page 1: ...ation manual Instructions pour l installation Einbau anleitung Instrucciones de montaje Instrusioni per l installazione Monteringsanvisningar Prirocnik z navodili za uporabo Installatiehandleiding 12 2 N80 N90 N100 N109 N110 N112 N145 REFRIGERATOR Ref 0305 ...

Page 2: ...Px x 821 x 525 x 543 97 91 11 3 3 340 30 Manual piëzo N100 Ex x 821 x 525 x 543 97 91 11 3 3 340 30 Electric N100 Ax x 821 x 525 x 543 97 91 11 3 3 340 29 5 Smart Energy Selection N109 Ex x 821 x 525 x 543 103 95 11 3 3 340 26 5 Electric N110 Px x 821 x525 x 603 103 95 11 3 0 340 30 5 Manual piëzo N110 Ex x 821 x 525 x 603 103 95 11 3 0 340 30 5 Electric N112 Px x 821 x 525 x 632 113 107 11 3 1 34...

Page 3: ...3 3 5 4 FIGURES 2 ...

Page 4: ...4 6 7 8 FIGURES ...

Page 5: ...5 9 10 FIGURES FIGURES N145 ...

Page 6: ...6 Model H W D Hst Dst N80 825 490 515 220 235 N90 825 529 515 220 235 N100 825 529 515 N109 825 529 515 N110 825 529 515 N112 825 529 568 220 235 N145A 1250 529 515 N145E 1305 529 515 11 12 FIGURES ...

Page 7: ...7 13 14 15 16 FIGURES ...

Page 8: ...8 17 FIGURES ...

Page 9: ...9 18 FIGURES ...

Page 10: ...10 19 FIGURES ...

Page 11: ...11 20 FIGURES ...

Page 12: ...ETY INSTRUCTIONS 13 3 DETERMINING WHERE TO IN STALL THE REFRIGERATOR 14 4 OUTSIDE VENTS 15 5 COMBUSTION GASES OUTLET 16 6 REFRIGERATION INSTALLATION 16 7 ELECTRICAL COMPONENTS 17 8 GAS CONNECTION INSTALLATION 19 9 WIRING DIAGRAMS 19 ENG ...

Page 13: ...K DE IS NL SE FI NO G30 Butane G31 Propane EN 732 specifications for liquid gas appliances Absorption refrigerators FIGURE 1 Specifications of other refrigerator models A B C D E F G H I Model Measurements H x B x D mm depthincl door Grossvolume incl freezer L Net volume incl freezer L Volume freezer L Input kWh 24 h Input gr 24h Net weight kg Operation average energy use at a surrounding temperat...

Page 14: ...rigerator and its extractor must be installed in a way that allows easy access for maintenance and repairs The installation and connections must satisfy the most recent technical regulations The refrigerator is designed for powering by liquid gas butane and propane 12V DC or 230VAC The performance of the refrigerator may be affected by adjacent heat sources such as an oven or stove Protect the ref...

Page 15: ...as to stream outside instead of building up on the floor A grating is used for this matter with the N80 90 112 models The other models N100 109 110 145 have a grating which is situated above floor level and therefore need an extra hole in the floor with a diameter in conformity with local regulations but we advice a diameter of at least Ø40 mm FIGURE 7 The upper ventilation grating The installatio...

Page 16: ...e outlet of the exhaust is in the position as shown in the drawing below It is important to always keep a distance of 5mm minimum from the vent The outlet of the exhaust tube has to be close to the bottom side of the vent When positioned correctly use the clamp to fix the exhaust tube to the flue of the refrigerator For refrigerator model N145 only You do not need to install a separate extractor T...

Page 17: ...igerator model 6 4 Fitting the door panel FIGURE 15 In order to fit the door panel the refrigerator s door needs to be demounted 1 Open the door unfasten the screw from the top hinge point with a screwdriver and remove the screw 2 Hold the door at a slight angle and lift the door from the lower hinge pen 3 Remove the 3 screws with which the lower cover is attached to the door 4 Remove the cover an...

Page 18: ...1 A fuse 7 3 Connecting to a DC power supply 12 V for all S ES models see figure 1 The description below applies to the installation in motor homes Please contact Thetford if you wish to install in any other vehicle The refrigerator is provided with a 3 wire 12v input cable red white black E powerless Engine signal to prevent 12v power supply from entering the heating device of the refrigerator wh...

Page 19: ...are in any doubt Take notice of the maximum life of the hose and replace it on time subject to the limits specified by the manufacturer or local regulations If the lower ventilation grating is not at floor level or slightly lower make a hole in the floor at the rear end of the refrigerator see figure 7 If a leak occurs this hole will allow the gas to stream outside instead of building upon the flo...

Reviews: