Change the travel latch position: (N404M and N504M
models only)
This refrigerator allows you to put the travel latch either at the
top of the door or at the bottom of the door regardless of the
door swing direction (See Art02539 and Art01570).
1. Change the position of the travel latch plate:
- Remove the screw [41] from the travel latch plate [162] on
the door.
- Remove the screw [41] from the filler plate [163] on the
oposite end of the door.
- Put the travel latch plate on the opposite end of the door.
- Attach the travel latch plate with the screw.
- Put the filler plate on the opposite end of the door.
- Attach the filler plate with the screw.
2. Change the position of the travel latch:
- Remove the screws from the travel latch [161].
- Put the travel latch on the opposite end of the
refrigerator.
- Attach the travel latch with the screws.
Connect the Electrical Components
The current draws are nominal values.
N304M models
AC Operation
240 volts AC
(216 volts min. - 264 volts max.)
Current Draw
0.8 Amps at 240 volts AC
DC Operation
12 volts DC
(11.5 volts min. - 15.4 volts max.)
Current Draw
12.0 Amps at 12 volts DC
14.0 Amps at 14 volts DC
N404M and N504M models
AC Operation
240 volts AC
(216 volts min. - 264 volts max.)
Current Draw
1.0 Amps at 240 volts AC
DC Operation
12 volts DC
(11.5 volts min. - 15.4 volts max.)
Current Draw
14.2 Amps at 12 volts DC
14.5 Amps at 12 volts DC (fan models only)
16.6 Amps at 14 volts DC
16.9 Amps at 14 volts DC (fan models Only)
This refrigerator operates on both AC and DC electrical sources. Operation out of these limits may damage the refrigerator’s electrical
circuit parts and will void the warranty.
The rear of the refrigerator cooling system has hot surfaces and sharp surfaces that can damage electrical
wiring. Make sure that there is a good clearance between all electrical wiring and the cooling system of the
refrigerator. Position any electrical wiring within the refrigerator enclosure opposite the burner side of the
refrigerator. Do not put any electrical wiring through the roof exhaust vent. Failure to correctly position