Installation Manual  7

Connect the Electrical Components

Electrical current necessary

:

DC Operation 

T1274

 models  - 12 volts DC voltage (10.4 volts min. - 15.4 volts max.)

Make no changes to any of the electrical wiring supplied with the refrigerator. Any changes that you would make to the electrical wiring 

will void the warranty.

Connect the 12

DC supply:

To reduce the risk of electrical interference from other DC appliances and induction from voltage spikes:

- The refrigerator must have an independent filtered 12V DC supply.

-

Route the DC power supply wires including the fuses directly from the power source to the refrigerator using either Option A or Option

 

B shown below.

Option A

Use a battery in parallel, in-between the refrigerator and the battery 

charger or an electrically filtered power converter. A fuse or circuit 

breaker should be wired as close to the power supply as possible.  

Option B

Wire the refrigerator directly to the electrically filtered DC power 

converter. The power converter must have a maximum DC ripple 

voltage less than or equal to 250mV. A fuse or circuit breaker 

should be wired as close to the power supply as possible.

- To connect the DC power supply wires, it is recommended to install 1/4” insulated female spade terminals or Stocko connector

W2041.100G to the connecting wire. (See Art 02740)

-

Alternatively, the connector may be cut off and the connection can be wired via closed-end

connectors (bell cap) or crimp connectors.  If the factory connector is cut off, proper care

should be taken by the OEM to assure that the connection is made properly. 

Thetford

 is

not

 

responsible for damage caused by improper capped or crimped connections.

(RED)

+

- As the distance from the power source to the refrigerator increases, the correct AWG wire

size also increases. Using longer than recommended wire lengths increases voltage drop and

increases the risk that the refrigerator may not turn back on after a drop in DC voltage. The

voltage required to start the compressor on the

 T1274 

 is 11.7 volts. The compressor will stop 

ART 02740

working when the voltage falls below 10.5 volts. The OEM should assure that the draw for all DC

powered equipment does not drop below 11.7 volts when the refrigerator is attempting to power on. If the refrigerator is operated on

 

battery power only, battery life can be extended by replenishing power through the use of solar panels or power from the tow vehicle

 

utilizing a wired 7-way plug.

Refrigerator 

2

5A Fuse  

12VDC 

Refrigerator 

2

5A Fuse 

(WHITE

)

Summary of Contents for T1274

Page 1: ...Installation Manual For Australian refrigerator models T1274 Part No 202176 08 2019 ...

Page 2: ...lations which need an electric outlet that is energized by an external power source the refrigerator must be electrically grounded as written in local codes or the National Electrical code NFPA 70 Incorrect installation adjustment alteration or maintenance of this refrigerator can cause personal injury property damage or both Obey the instructions in the Ventilation Requirements section of this ma...

Page 3: ...ctly The refrigerator has a built in vent at the top and clearance at the bottom Make sure that the flow of air through these vents is not blocked in any way Blockage of air through these vents can cause shortened life of the refrigerator cooling unit poor cooling performance of the refrigerator continuous operation of the refrigerator fast battery discharge void of the refrigerator warranty CAUTI...

Page 4: ...sary See Art02741 Refrigerator cabinet width 592 mm 1 Refrigerator cabinet height 1521 mm 2 Refrigerator top to control top 53 mm 3 Enclosure depth 610 mm 4 Refrigerator bottom feet to middle handles 1034 mm 5 Refrigerator bottom to bottom of feet 22 mm 6 Enclosure front to door front 75 mm 7 2 1 3 4 5 6 7 ART 02741 ...

Page 5: ...crew driver pop the handle out of the housing of each door Remove 2 screws and handle housing catch and spring from each door On the other side of the door remove one screw and remove the pocket cover Move the lower handle to the upper door and the upper handle to the lower door Attach each door handle and pocket cover with the screws 5 Lay the refrigerator on its side to access the bottom hinge S...

Page 6: ... 6 provided mounting screws 3 on each side Install hole plugs to cover screw holes Install the Refrigerator ART 02736 121 Safety Strap Mounting optional One of the screws 1 fastening the control bracket may be removed and reinstalled to fasten the strap or cable See Art02757 Alternatively a screw may be driven into the breaker in the specified 76 mm 3 0 inch by 38 mm 1 5 inch area shown Any strap ...

Page 7: ...e To connect the DC power supply wires it is recommended to install 1 4 insulated female spade terminals or Stocko connector W2041 100G to the connecting wire See Art 02740 Alternatively the connector may be cut off and the connection can be wired via closed end connectors bell cap or crimp connectors If the factory connector is cut off proper care should be taken by the OEM to assure that the con...

Page 8: ...rcuit at the refrigerator power supply leads to protect the controls of the refrigerator This amp should only be replaced with a 25A automotive fuse 3 Connect the DC power supply wires If the DC power supply leads are attached incorrectly the refrigerator will not operate Connect the positive DC power supply lead to the red wire 99 of the refrigerator Connect the negative DC power supply lead to t...

Page 9: ...ndby mode after 5 seconds Touch the NIGHT MODE 7 button to set the refrigerator to night mode Night mode will turn off automatically after 8 hours or if you push the night mode button again to turn the blue indicator light off This 8 hours can be changed by pressing the night mode button for 3 seconds After the 3 seconds the default 8 hour hours will be shown in the display To change this setting ...

Reviews: