Operation/installation/service manual
MACERATOR TOILETS
Manuale di utilizzo / installazione / manutenzione
TOILET MACERATRICI
X-light / Privilege/ Evolution/ Breeze/ E-Breeze/ Silence Plus 2G/ Elegance 2G
61
TECMA SRL – Via Flaminia / Loc Castel delle Formiche/ 05030 Otricoli (TR) / Italy-
rev 1.2017
1111111111111111
111111111111111111111
The Full Tank Sensorhas to attached at the highest point on the tank for the tank’s capacity, or
where the installer wants the Tank Full level to be.
The sensor has a removable cover over the pressure-sensitive adhesive pad.
In case of installation with premium control units, it is not necessary the use of the STA.
3.7 Equipment required
- Electric drill with insert or screwdriver for the stainless steel straps.
- Electric drill or screwdriver to tighten the assembly screws
- Jig saw to make the control panel housing
- Adjustable wrench to tighten the solenoid valve
3.8 SYSTEM
Power supply:
On the rear side of the product there is a label that specifies the power voltage value:
12v /24 v/110 v/230 v (refer to section 8 for electric wiring)
Clean water supply
:
TECMA toilets can be used with water coming from a single pump/autoclave
(centralised systems) or from a single inlet pump connected to a sea cock (single systems).
WARNING: DO NOT USE the solenoid valve with sea water
Blackwater discharge
: TECMA toilets have powerful macerator pumps, which push blackwater to
the collection tanks.
WARNING: Toilet configuration (A). The toilet is installed below the floating line. Install a
VENT VALVE at a height greater than the line. See fig. 1.
WARNING: Toilet configuration (B). Toilet installed above the floating level. Install a VENT
VALVE to prevent siphoning phenomena that may cause unpleasant odours. See fig. 1.