© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
021821/08/21
Tel. +49 551 79001-0 · Fax +49 551 79001-65 · info@thiesclima.com ·
Page 46 of 102
The following table shows the exported files:
Subfolder
File name
Content
-
config.txt
Configuration (INI file).
-
config_ChList.bid
Channel configuration (binary format).
-
config_DevList.bid
Devices configuration (binary format).
-
logfile.txt
Log file in the ASCII format.
ARCH_AVx
YYYYMMDD.txt
YYYY year
MM month
DD day
Day file for the average value archive
“x”, with the measured values in the
ASCII format.
ARCH_EXy
YYYYMMDD.txt
YYYY year
MM month
DD day
Day file for the extreme value archive
“y”, with the measured values in the
ASCII format.
Table 5: Files on SD card
One can export from any Data loggers on an SD card by saving the data in a directory,
depending on the clear Data logger hardware ID.
If the data of a Data logger are exported again onto the same SD card, existing data on the
SD card is overwritten. This is only a problem if the configuration of the Data logger has
changed between the export processes.
Comments:
The user is responsible for using a SD card with enough free storage.
The write-protection switch of the SD card is not used by the Data logger.
We urgently recommend that the data be backed up on other media.
Do not remove the card during writing.
Liability on our part for the loss of the data on the SD card is ruled out.