© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
021821/08/21
Tel. +49 551 79001-0 · Fax +49 551 79001-65 · info@thiesclima.com ·
Page 58 of 102
7.2 Commands
The following table shows the available commands, and the corresponding passwords for
reading and writing:
Command
Initial value
factory
setting
Description
Password
reading
1
/ writing
2
0
Reading of the archive ID.
Without
-
0 (8N1)
Choosing of the framing for COM1.
Without
User
0 (8N1)
Choosing of the framing for COM2.
Without
User
0 (8N1)
Choosing of the framing for USB.
Without
User
Command BR_COM1
96
Choosing of the baud rate for
COM1.
Without
User
Command BR_COM2
96
Choosing of the baud rate for
COM2.
Without
User
Command BR_USB
1152
Choosing of the baud rate for USB.
Without
User
-
Readout archive configuration.
Without
-
0
DHCP
Without
User
-
Stop readout process
Without
Without
-
Reading/setting date
Without
User
1
Quick start mode.
Without
User
-
Read hardware ID
Without
-
0 (THIES)
1 (MODBUS)
Identification number and/or slave
address.
Without
User
0
IP address
Without
User
0
IP-Gateway
Without
User
0
IP subnet mask
Without
User
0
Set key / password.
Without
Without
0
Language used in the display.
Without
User
-
Logger status.
Without
-
0
Output of the instantaneous values.
Without
User
0
Output of the instantaneous values.
Without
User
0
Output of the average values.
Without
User
0
Output of the extreme values.
Without
User
0
Request reset source or carry out
reset.
Without
User
-
SW version.
Without
-
0
WLAN Status
Without
User
0
WLAN IP-adress
Without
User
0
WLAN DHCP
Without
User
0
WLAN IP-Gateway
Without
User
0
WLAN IP-subnet mask
Without
User
-
WLAN PSK
Without
User
-
WLAN SSID
Without
User
Table 8: Command list
1
)
: Command without parameter (used to read the set parameter).
2
)
: Command with parameter (used to write a new parameter).