9 WEB-Server
The DLU is equipped with a WEB server that supports a WEB display of the instantaneous
and archive values. Via the submenu
LAN and WiFi settings and also logins can be made
and set.
To use the WEB page, the DLU must be connected to the internet or a local network via a
LAN connection and a valid IP address for the network must be set in the logger (see 4.5
network module). The WEB server can be accessed from any computer with a WEB browser
in the same network by entering the IP address of the logger in a WEB browser.
Figure 46: IP-address in WEB browser
A correct entry always begins with
http://
, followed by the IP address e.g.
217.91.124.74
.
Each of the numbers separated by dots can be between 0 and 255. After successfully
entering the IP address of the logger and confirming with the Enter key, the start page of the
DLU is displayed with the current values.
After restarting the logger, it can take up to
5 … 15 minutes
for the data on the WEB server
to be displayed. Use the and buttons
to scroll through the DLU menu until the
Ethernet settings page is visible. The IP address used is displayed there.
If your PC or your local network supports the mDNS (Multicast DNS) service, you can also
enter “dlu.local” in the browser. Then the WEB page of the DLU is also called up with this
address.