Following table shows the allocation of the connection terminals of the Data logger:
Terminal
Signal
1
Supply 24Vac/dc
2
3
+
12V accumulator
4
-
5
+
12V solar
6
-
7
12V
Sensor supply
8
GND
9
A
PT100
10
a
11
e
12
E
13
+
0-1V humidity
14
-
15
Analogue IN1
16
IN+
17
IN-
18
Supply -
19
Analogue IN2
20
IN+
21
IN-
22
Supply -
23
Analogue IN3
24
IN+
25
IN-
26
Supply -
27
GND / AGND
28
THIES serial 2
CLK (clock)
29
DI (data)
30
THIES serial 1
CLK (clock)
31
DI (data)
32
12V supply (switchable)
+
33
-
34
COM2
RX+
35
RX-
36
TX+
37
TX-
38
GND-COM2
39
COM1
RX+
40
RX-
41
TX+
42
TX-
43
GND-COM1
44
Digital
OUT2
+/-
45
+/-
46
Digital
OUT1
+/-
47
+/-
48
Digital
IN2
+
49
-
50
Digital
IN1
+
51
-
52
Earth
Table 2: terminal allocation