© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
021821/08/21
Tel. +49 551 79001-0 · Fax +49 551 79001-65 · info@thiesclima.com ·
Page 59 of 102
User password: 234
7.2.1 Command ArchID
<id>ArchID<parameter><CR>
Archive ID
Access:
Reading
Description:
With the command “ArchID”, the archive identification
number is read.
Parameter description:
Value range:
0...99999999
Initial value:
0
7.2.2 Command BP_COM1
<id>BP_COM1<parameter><CR> Setting the framing COM1
Access:
Reading / writing
Description:
With the command BP_COM1, the desired framing is
set for COM1.
Parameter description:
Parameter
Description
8N1
8 data bits, no parity, 1 stop bit
8O1
8 data bits, uneven parity, 1 stop bit
8E1
8 data bits, even parity, 1 stop bit
8S1
8 data bits, Space parity, 1 stop bit
8M1
8 data bits, Mark parity, 1 stop bit
Value range:
8N1 / 8O1 / 8E1 / 8S1 / 8M1
Initial value:
8N1