Q-Series Chassis, Rev. D
12
October 2018
Removable mounting
brackets installed for
under-desk mounting.
Removable mounting
brackets installed for
fixed desktop mounting.
K2 K1
K2 K1
UPDATE
UPDATE
USB HID
LINE OUT
LINE OUT
MIC IN
MIC IN
VQM-HA0002-LCRX
USB HID
2
1
2
1
K2 K1
K2 K1
UPDATE
UPDATE
USB HID
LINE OUT
LINE OUT
MIC IN
MIC IN
VQM-HA0002-LCRX
USB HID
2
1
2
1
Q-1300 Mounting Bracket Configurations
2.3 Cooling
The Q-4300 Extender System uses four DC fans to move air horizontally through the enclosure.*
The Q-2300 Extender System uses two DC fans to move air horizontally through the enclosure.*
The Q-1300 Extender System uses passive ventilation through chassis vent holes.
Note: Be sure to leave adequate ventilation space on both sides of the units
(2”minimum), especially if the units are being stacked
2.4 Hot Swappable Power Supplies
Each Q-4300 Chassis is equipped with dual hot-swappable, current-sharing power supply
modules. Each supply has an ON/OFF rocker power switch located on the chassis front panel. When
the power supply is ON, the LED on the front of the power supply will be lit.
If a power module ever fails, the replacement can be swapped with no interruption in unit
functionality. To hot swap a power supply, simply unscrew the affected module and replace it with a
new power supply module which can be ordered from Thinklogical (part number VTM-000001).
2.5 Front Panel Display and Navigation Buttons
Note: On the Q-4300 and Q-2300 Chassis front panel display is a removable decal
that identifies the installed modules as configured for your specific application.
The Q-4300 and Q-2300 front-panel LCD display should be visible and accessible for system setup. The
front panel buttons are used to gather status, configure special video settings and to review existing
configurations.
Power ON/OFF Update Port LCD LCD Navigation
Q-4300 Chassis Front Panel
*See Mixing Q-Series Modules and TLX Modules in a single Chassis on page 8.