S e c u r e C o n s o l e S e r v e r M a n u a l , R e v . K , J u l y , 2 0 1 3
Page 25
The SCS480R Power Module is mounted in the front panel of the SCS480R and has the
same capabilities as the SCSR and Sentinel Modules. It is not necessary to remove the DC
power cord from the SCS480R when replacing a module.
!
Note: The Power Modules in the SCS160/320/480 are
NOT FIELD
SERVICEABLE.
This option only applies to the SCS80R, SCS160R, SCS320R,
SCS480R and Sentinel 32.
Each -48VDC Power Module can fully support the SCS80R, SCS160R, SCS320R, SCS480R
and Sentinel 32 systems. However, the intended design is to have two power sources
running your SCS system. When both supplies are active, they will share the system load. If
one fails, the remaining supply can then take the full load.
The SCS80R, SCS160R, SCS320R, SCS480R and Sentinel 32 ship with two WAGO
MCS connectors, one for each module, to allow separate DC power source connections.
Plug the WAGO MCS connector into the SCS DC Power Module and connect to a regulated
DC power source.
3.4.1 Wiring the -48Vdc Connector
WAGO MCS DC Power Connector:
1. Brown
= -48VDC
2. Green/
Yellow
= Chassis Ground
3. Blue
= Common
The WAGO DC Power Connector
consists of 3 pieces: The connector plug
and two halves of the strain-relief back
shell. After installing the wires as
depicted above, the three pieces fit
together as shown (right) and snap firmly
into place.