background image

Summary of Contents for S3600TL

Page 1: ......

Page 2: ...r certified by the local electrical authority Copyright The copyright of this manual belongs to Wuxi Xinqi Power New Energy Technology Co Ltd Any part or the entire of this manual cannot be carried in public without a written permission Because of the continuous product upgrading this manual will be updated correspondingly and thus there will be some unconformity between the manual description and...

Page 3: ...or death directly if this warning is neglected Danger Warning Caution Notice It means a moderately potential danger which may cause a serious personal injury or death directly if this warring is neglected It means a lightly potential danger which may cause a light or moderate personal injury or serious property loss if this warning is neglected It means a potential risk which may cause device malf...

Page 4: ...f high temperature and burn injury The wasted product must be sent to the authorized collecting center Please carefully read through and fully understand the instruction manual before using the product Contents 1 Safety instruction 1 1 1 Before installation 1 1 2 During installation 2 1 3 Operation 2 1 4 Repair 2 1 5 EMC 3 2 Product description 4 2 1 Product applicability 4 2 2 Circuit structure 4...

Page 5: ...eck 29 4 2 Electrify the inverter 29 5 Human machine interaction 30 5 1 LCD interface 30 5 2 Internal data storage 31 5 3 Introduction to the function of monitor software 31 5 3 1 Main interface 32 5 3 2 Parameter setting 32 5 3 3 Device management 33 5 4 Inverter working mode 33 5 4 1 Standing by mode 34 5 4 2 Ready mode 34 5 4 3 Power generating mode 35 5 4 4 Protection mode 35 5 4 5 Fault state...

Page 6: ...nk Power is not responsible for any damage or loss caused by misuse or misunderstanding the information in this manual Misuse or misoperation may harm The personal safety of the operator or a third person The property safety of the inverter or any other property Warning Notice Warning 1 1 Before installation The inverter cannot be connected to the grid unless approved by the electrical authority a...

Page 7: ...e or loss Be aware of the hot surface while the device is running 1 4 Repair Completely switch off the connection between the inverter and the grid DC side connection Wait for 10 minutes until the internal elements are fully discarged Do NOT restart the inverter before all the hazards have been removed Please contact your local dealer and always have licensed trader do the repairing 1 5 EMC EMC El...

Page 8: ...nd output EMC can effectively reduce the interference between the inverter and outside CPU1 and CPU2 control the inverter operation and monitor the operation state and in any abnormal working condition it will protect the inverter and external device and personal safety according to the reserve program thus extremely improve the stability and reliability of the system Fig 2 2 2 3 Product introduct...

Page 9: ......

Page 10: ...ce assembly so please contact the local authoriz ed installation and maintenance technist if you need to maintain your inverter The product is carefully tested and checked before transportation however it is still possible to be damaged during transportation please check the device again before installation I f any damage please contact the transportation agency or directly contact Wuxi X inqi Pow...

Page 11: ...k the inverter shall be installed beyond reach of children The temperature of some parts e g the heat radiator is high when the inverter is running Make sure the installation position does not shake The inverter shall be installed in a well ventilated place to ensure the normal heat radiation The installation place shall be firm enough to support the inverter weight The inverter shall be installed...

Page 12: ...e short circuit current and maximum power at S TC of the PV array are within the capacity of the solar inverter The full load M PPT voltage range is within the 250V 480V 2 Drill holes in the marked position as per the siz e of expansion screws 3 I nsert the expansion tubes into the hole knock the tubes into the hole and make them level with the wall surface 5 K eep the inverter tilts slight upward...

Page 13: ...y Wiring operation must be performed by a qualified electrical engineer All electrical installation must be complying with local and national electrical standards Warning Warning The inverter cannot be connected to the grid unless approved by the local electrical authority and all electrical connections are completed by a qualified electrical engineer Please use cables of specification recommended...

Page 14: ...then connected to the A B terminal on the RS 485 U S B switch and the other end of the switch is connected to the computer U p to 32 inverters can be connected by this mode Fig 3 16 The M ulti device communication mode 2 with RS 485 and WI FI is applicable for centralize d installation where wiring is not convenient between the computer and devices Tip Fig 3 15 The M ulti device communication mode...

Page 15: ...ence The DC side of inverter has 4 terminals totally including two DC positive wiring terminals and two DC negative wiring terminals S ee the figure below The two pairs of A B RS 485 communication wiring terminals at the inverter communication side are equivalent S ingle device communication Either pair of A B RS 485 communication wiring terminals can be connected if RS 485 module is connected M u...

Page 16: ...th the MPPT voltage of the serial array must comply with the MPPT voltage in the PV grid tied inverter Protect the LCD panel during wiring Protect the LCD panel and other elements from scratch or damage by cables or tools 1 Using the striping tool to cut the PV cable and makes the cooper wire reveal as 0 7cm In order to balance each PV series Cable shall be with the same sectional area Different c...

Page 17: ...into the mold of 4 6mm 3 Process crimping 4 Crimp closely between the terminal and PV cable 5 The terminal is crimped well with PV cable wire 6 Put terminal into connector 7 The DC wiring finished 3 6 4 2 Steps for AC connection Steps for AC cable wiring 23 Installation Fig 3 31 Fig 3 28 Fig 3 29 Fig 3 30 Fig 3 32 Fig 3 33 ...

Page 18: ...ing terminal into corresponding DC terminal Fig 3 38 3 Insert the AC wiring terminal into the AC terminal 4 Switch on the AC breaker 5 Switch on the DC breaker Installation Screw the green yellow wire to the ground terminator in the AC Connector Screw the blue wire to the N Natural terminator in the AC Connector Screw the brown wire to the L Line terminator in the AC Connector DC1 DC1 DC2 DC2 AC O...

Page 19: ...metal section of the tube type pre insulated terminal and press on the terminal by a pair of wire end sleeve pliers reliably 1 Remove the 6 screws on the inverter bottom cover by wrench and open the bottom cover 4 Press down the top of the terminal by a flat screw driver insert the cable into the terminal A B Fig 3 45 A1 B2 B1 A2 5V GND 098 06013 00 710 06013 00 1 9 2 10 CN1 U4 8 5 4 U3 LD2 LAB1 1...

Page 20: ...nd support has enough load bearing capacity Check if all cables in the system are firmly connected without any missed or wrong connection and especially check if all positive and negative poles are correct If a DC switch is equipped on the inverter the DC switch shall be turn to the OFF state Make sure the DC input voltage of the inverter is lower than 550V with the temperature decrease of the PV ...

Page 21: ...rd Running state information record It can save the running state of the device including the start time point and end time point of the running state so that the user can check the running state conveniently Song series inverter can realize data reviewing and parameter setting ect by the monitor software the following is a brief introduction to the monitor software and for more details please rea...

Page 22: ...ake no consequential responsibility 5 3 2 Parameter setting 1 Serial port setting select the serial port number for device communication 2 Device selecting select the device to be set 3 Time setting set the time of the current device 5 3 1 Main interface 3 Current device current data curve 2 Accumulated data displaying zone current power generated current day power generated total power generated ...

Page 23: ...ardware self checking and after the self checking is over the inverter enter power generating mode If any external fault such as AC side grid fault is detected by the inverter the inverter will stop power generating and enter the protection mode in this case the protection indicator on LCD panel will show and display the corresponding protection code Troubleshooting can be performed by the user ac...

Page 24: ...the internal fault is removed It will be reenter the grid connect power generating mode if the fault is removed The LCD will enter sleep mode if no operation last for 2 minutes to wake it up please tap on the shell slightly In the morning and evening the light intensity is weak and changeful thus the LCD keep flashing In order to avoid the user s trouble and the LCD will light up when it enter int...

Page 25: ... from the protection state if the system is correctly designed and installed Sometimes the inverter enters the protection state by the own defect and can be recovered by resetting or repairing The fault state is caused by incorrect design of system e g the DC voltage is too high and thus the inverter acts to protect the system safety The inverter can be recovered from some faults automatically or ...

Page 26: ...he DC breaker 2 Check if DC2 voltage is higher than 550V 3 If the fault above is removed but the inverter can still not work normally please ask for professional service 1 Switch off the DC breaker 2 Check if DC1 voltage is higher than 550V 3 If the fault above is removed but the inverter can still not work normally please ask for professional service E002 It is unnecessary to maintain the inverte...

Page 27: ...package if possible If the original package is not available please pack with a carton satisfying the following requirement Firm enough for 45kg Easy for handing Fully closeable 1 Switch off the AC breaker 2 Switch off the DC breaker 3 Wait for 10min till the inverter is fully discharged 4 Check by a multimeter and make sure neither the AC side nor the DC side is electrified 5 Press the right posi...

Page 28: ...uropean Efficiency MPPT efficiency Protection DC reverse polarity protection Short circuit protection Ground fault residential current General Parameters Dimension L W H mm Weight kg Night Mode support Night Mode support Isolation type Protection degree Operation temperature ºC Heat Dissipation Acoustic noise level dB Altitude m Storage temperature ºC Real Time Clock module LCD Display Communicati...

Page 29: ...y assurance 9 1 Warranty Policy For our customers we provide 5 years standard warranty from the date of installation you can also upgrade your standard warranty to 10 years Please keep the purchasing invoice and trade mark clear for warranty For more information please contact Think Power or your local dealer 9 2 Exception clause Any of the following situation will not be covered by our warranty p...

Page 30: ...h us for any product problem Add Room 103 Building No 1 A District 530 Development Zone No 100 Jinxiu Road Binhu District Wuxi Jiangsu Province China Tel 0086 510 85192198 Fax 0086 510 85192197 Post Code 214125 E mail xq xqsolar com sale xqsolar com Web Http www xqsolar com Contact Think Power ...