For each output of the amplifier, the total impedance resulting from the loudspeakers con‐
nected to it must not be below the allowed minimal impedance of the amplifier output. If you
connect more than one loudspeaker to an amplifier output, please note the following:
n
If the loudspeakers are connected in a series, the individual impedances will be added up.
n
If the loudspeakers are connected in parallel, the reciprocal of the total impedance equals
the sum of the reciprocals of the individual impedances.
Example: If you have two loudspeakers with the same impedance, their impedance doubles if
they are connected in a series, their impedance halves if they are connected in parallel.
For detailed information related to this topic please refer to our Online Guide
‘
PA Speakers
’
(
www.thomann.de
).
The device has been designed for rack mounting in a standard 19-inch rack; it occupies two
rack units.
Rack mounting
Installation and operation
power amplifier
16
Summary of Contents for t.amp E-400