background image

 

 

Safety instructions

 

 

This device amplifies electric audio frequency signals to operate passive speakers. Use the

device only as described in this user manual. Any other use or use under other operating con‐

ditions is considered to be improper and may result in personal injury or property damage. No

liability will be assumed for damages resulting from improper use.
This device may be used only by persons with sufficient physical, sensorial, and intellectual

abilities and having corresponding knowledge and experience. Other persons may use this

device only if they are supervised or instructed by a person who is responsible for their safety.

DANGER!
Danger for children
Ensure that plastic bags, packaging, etc. are disposed of properly and are not

within reach of babies and young children. Choking hazard!
Ensure that children do not detach any small parts (e.g. knobs or the like) from

the unit. They could swallow the pieces and choke!
Never let children unattended use electrical devices.

Intended use

Safety

Safety instructions

 

 

TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X

7

Summary of Contents for the t. amp TA 1050 MK-X

Page 1: ...TA 450 MK X TA 600 MK X TA 1050 MK X TA 1400 MK X TA 2400 MK X power amplifier user manual ...

Page 2: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 14 08 2012 ...

Page 3: ...s 7 3 Features 12 4 Installation and starting up 13 4 1 Pin assignment 13 5 Connections and operating elements 17 6 Technical specifications 22 7 Protecting the environment 25 Table of contents TA 450 MK X TA 600 MK X TA 1050 MK X TA 1400 MK X TA 2400 MK X 3 ...

Page 4: ... sure that it is available to all persons using this device If you sell the device include the manual for the next owner Our products are subject to a process of continuous development We therefore reserve the right to make changes without notice This section provides an overview of the symbols and signal words used in this user manual Symbols and signal words General notes power amplifier 4 ...

Page 5: ...ymbol and signal word indicates a possible dangerous situation that can result in minor injury if it is not avoided NOTICE This combination of symbol and signal word indicates a possible dangerous situation that can result in material and environmental damage if it is not avoided Warning signs Type of danger Warning high voltage General notes TA 450 MK X TA 600 MK X TA 1050 MK X TA 1400 MK X TA 24...

Page 6: ...Warning signs Type of danger Warning danger zone General notes power amplifier 6 ...

Page 7: ...d intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety DANGER Danger for children Ensure that plastic bags packaging etc are disposed of properly and are not within reach of babies and young children Choking hazard Ensure that children do not detach any sm...

Page 8: ... serviceable parts inside DANGER Electric shock caused by short circuit Always use proper ready made insulated mains cabling power cord with a pro tective contact plug Do not modify the mains cable or the plug Failure to do so could result in electric shock death or fire If in doubt seek advice from a regis tered electrician Safety instructions power amplifier 8 ...

Page 9: ...amage Decrease the volume level immediately if you experience ringing in your ears or hearing impairment If this is not possible keep a greater distance or use suffi cient ear protectors CAUTION Risk of injury due to heavy weight Due to the heavy weight of the device at least two persons are required for trans port and installation Safety instructions TA 450 MK X TA 600 MK X TA 1050 MK X TA 1400 M...

Page 10: ...ect heat source Keep the device away from naked flames NOTICE Operating conditions This device has been designed for indoor use only To prevent damage never expose the device to any liquid or moisture Avoid direct sunlight heavy dirt and strong vibrations Safety instructions power amplifier 10 ...

Page 11: ...hock or fire NOTICE Magnetic fields The device generates strong magnetic fields that can interfere with the function of poorly shielded devices The strongest magnetic fields are directly above and below the power amplifier Therefore never place sensitive devices such as pre amplifiers radio transmission systems or tape decks directly above or below the power amplifier When installing the power amp...

Page 12: ... 2 screw terminals n Protection circuits Audio limiter Thermal protection Short circuit protection DC protection Overcurrent Subsonic noise protection n Cooling via integrated two stage fans n Suitable for 19 racks 2 RU installation depth 44 cm Features power amplifier 12 ...

Page 13: ...ckaging or your own packaging material suitable for transport or storage respectively Establish all connections as long as the unit is switched off Use the shortest possible high quality cables for all connections 4 1 Pin assignment You can use XLR and 1 4 plugs with balanced or unbalanced wiring In the following we will give you an overview of the various options Installation and starting up TA 4...

Page 14: ...rawings and tables indi cate the XLR pin assignment Balanced wiring 1 Ground shielding 2 Positive signal 3 Negative signal Unbalanced wiring 1 Ground shielding 2 Signal 3 Bridged to pin 1 XLR connections for signal inputs Installation and starting up power amplifier 14 ...

Page 15: ...he pin assignment of a 1 4 phone plug to be used Balanced wiring 1 Tip Positive signal 2 Ring Negative signal 3 Sleeve Ground shielding Unbalanced wiring 1 Signal 2 3 Ground shielding 1 4 phone sockets for signal inputs Installation and starting up TA 450 MK X TA 600 MK X TA 1050 MK X TA 1400 MK X TA 2400 MK X 15 ...

Page 16: ...The drawing alongside shows the pin assignment of the lockable NL4 mounting connectors NL4 mounting connectors Installation and starting up power amplifier 16 ...

Page 17: ...5 Connections and operating elements Front panel Connections and operating elements TA 450 MK X TA 600 MK X TA 1050 MK X TA 1400 MK X TA 2400 MK X 17 ...

Page 18: ... Clip and fault condition Fault an During operation the Power LED lights up constantly The Signal LEDs respond to the input signal If one of these LEDs lights up without an input signal is present dis connect the speakers from the amp and turn the input gain control of both channels down to minimum If the LEDs continue to light up the device must be inspected by an authorized service centre Connec...

Page 19: ...Rear panel Connections and operating elements TA 450 MK X TA 600 MK X TA 1050 MK X TA 1400 MK X TA 2400 MK X 19 ...

Page 20: ...nectors for signal inputs 8 IN A IN B 1 4 phone sockets for signal inputs 9 STEREO PARALLEL BRIDGED switch Switch to select the operating modes STEREO both channels operate independently of each other PARALLEL the inputs of both channel are interconnected and BRIDGED both channels are interconnected to form one channel with double output power Connections and operating elements power amplifier 20 ...

Page 21: ...d in the unit This prevents ground loops position Lift switch is not pressed no connection Position Ground switch is pressed earth pin and signal ground are electrically connected 11 IEC chassis connector for operating voltage supply Connections and operating elements TA 450 MK X TA 600 MK X TA 1050 MK X TA 1400 MK X TA 2400 MK X 21 ...

Page 22: ...wer RMS 4 W stereo 2 200 W 2 300 W 2 525 W 2 700 W 2 1200 W Output power RMS 8 W mono bridged 300 W 450 W 800 W 1200 W 2000 W THD 4 W 1 kHz 0 05 200 W 0 05 300 W 0 05 525 W 0 05 700 W 0 05 1200 W IMD SMPTE 60 Hz 7 kHz 0 01 125 W 0 01 200 W 0 01 350 W 0 01 450 W 0 01 650 W Damping factor 8 W 1 kHz 300 1 350 1 500 1 Voltage gain 50 standard 70 standard 91 standard Technical specifications power ampl...

Page 23: ...itivity 0 775 V rated power 8 W Input impedance 20 kW balanced 10 kW unbalanced Signal to noise ratio 103 dB Crosstalk 60 dB Protective circuits DC thermal short circuit subsonic noise and overcurrent protection Cooling two controlled DC voltage fans Operating supply voltage AC 230 V 50 60 Hz Technical specifications TA 450 MK X TA 600 MK X TA 1050 MK X TA 1400 MK X TA 2400 MK X 23 ...

Page 24: ...00 MK X TA 1050 MK X TA 1400 MK X TA 2400 MK X Dimensions W H D 483 mm 103 mm 475 mm 485 mm 103 mm 470 mm 483 mm 103 mm 475 mm Weight 13 3 kg 13 7 kg 16 4 kg 17 5 kg 19 7 kg Technical specifications power amplifier 24 ...

Page 25: ...w the notes and markings on the packaging This device is subject to the European directive 2002 96 EC Do not dispose of the device with your normal household waste Dispose of this device through an approved waste disposal firm or through your local waste facility When discarding the device comply with the rules and regulations that apply in your country If in doubt consult your local waste disposa...

Page 26: ...Notes power amplifier 26 ...

Page 27: ......

Page 28: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany www thomann de ...

Reviews: