F - uSiNG THE prOduCT

30Nm drive kit 
for rolliNg shutters aNd bliNds

1 - USING THE PRODUCT WITH THE REMOTE 
CONTROL

•  You can raise and lower the controlled shutter 

using the buttons for the channel used during 
pairing. Pressing the '

ON

' button opens the 

shutter. Pressing the '

OFF

' button closes the 

shutter.

•  During opening, pressing the '

OFF

' button 

stops the shutter at that point. • 

During 

closing, pressing the '

ON

' button stops the 

shutter at that point.

•  The '

ALL ON

' and '

ALL OFF

' buttons 

simultaneously operate all paired devices on 
channels 1, 2 and 3.

2 - USING THE PRODUCT WITH ANY DEVICE

•  You can control the speed at which the shutter 

raises and lowers from any device paired to 
the module. Refer to the user guide for each 
of the paired devices to find out how to open 
and close the shutter.

•  During opening, pressing the close button 

stops the shutter at that point. During closing, 
pressing the open button stops the shutter at 
that point.

3 - USING THE PRODUCT WITH THE 
THOMBOX

•  When you pair your module with a Thombox, 

your module will appear in the '

Ouvrants 

[Openers]

' widget. It also appears as an 

'Actionneur [Actuator]' in the rule creator. You 
can then create rules to manage when your 
shutter opens and closes.

•  When you pair your remote control with a 

Thombox, it does not appear in the dashboard 
but is available in the rule creator in the 
'

Contrôles [Controls]

' section. You can then 

create rules which you can trigger using the 
buttons on your remote control.

4 - DELETING A DEVICE FROM THE REMOTE 
CONTROL MEMORY

To remove one of the devices controlled using 
a channel on the remote control, repeat the 
programming steps in this guide with the relevant 
channel. By programming a device twice on the 
same channel, the device is removed from the 
channel.

5 - REMOVING ALL DEVICES FROM A 
REMOTE CONTROL CHANNEL

•  To delete all devices operated via one remote 

control channel, press and hold the 'on' and 
'off' buttons for the relevant channel for 3 
seconds.

•  Release the buttons, then once again hold the 

'on' and 'off' buttons for 3 seconds.

All appliances controlled via this channel will then 
be deleted from the memory.

6 - CLEARING FEATURE

The clearing feature of the remote control allows 
you to remove all unused devices from a channel 
(e.g. a remote-controlled socket which is no longer 
available to you).

•  To clear a channel on the remote control, 

press and hold the 'on' and 'off' buttons for 
the relevant channel for 3 seconds.

•  Release the buttons, then hold the 'on' button 

for 3 seconds.

If a device fails to respond 20 times in a row after 
the relevant channel button is pressed, it has been 
deleted from the memory. All other devices which 
are still in use remain in the memory.

Summary of Contents for 500014

Page 1: ...EN 30Nm drive kit for rolling shutters and blinds ref 500014 70Kg 3m www thomsonbox eu v2...

Page 2: ...08 D INSTALLATION 09 1 INSTALLING THE TUBULAR MOTOR 09 2 INSTALLING THE MANAGEMENT MODULE 16 3 CONNECTING THE MANAGEMENT MODULE 16 4 REMOTE CONTROL 17 E CONFIGURATION 18 1 PROGRAMMING 18 2 SETTING MOT...

Page 3: ...7 USING THE GROUP SELECTOR 21 8 REPLACING THE REMOTE CONTROL BATTERY 21 9 MOTOR SAFETY FEATURES 21 G FAQ 22 H TECHNICAL AND LEGAL INFORMATION 23 1 technical characteristics 23 2 warranty 24 3 help and...

Page 4: ......

Page 5: ...eplaced by an original part and nothing else Periodically check the installation for any signs of wear or damage to the shutter the mechanical parts and the mounting Do not use the device if repairs o...

Page 6: ...r tube connector ring 4 Head adaptor 1 End stop configuration button 2 Shutter tube connector ring location 3 Output shaft only driven part in the whole motor 5 Snap ring 6 Pin 7 Management module 8 R...

Page 7: ...Terminal blocks for connecting to the motor and the mains supply 30Nm drive kit for rolling shutters and blinds 4 remote control 2 4 3 5 1 6 7 1 System on indicator light 2 Channel 1 2 3 on buttons 3...

Page 8: ...ghting etc openers shutter motors garage doors etc and manage your energy use heating and electricity consumption with just a few clicks on a computer touchscreen tablet or smartphone from anywhere in...

Page 9: ...9 EN D INSTALLATION 30Nm drive kit for rolling shutters and blinds 1 INSTALLING THE TUBULAR MOTOR Remove the rolling shutter cover...

Page 10: ...e the shutter housing drive plate Remove all obstacles so that there is a flat surface Strengthen if required Note the axis of the axle that the motor will replace then place the motor anchor plate al...

Page 11: ...11 EN D INSTALLATION Align the slots on the ring with the motor collar Attach the head adaptor 30Nm drive kit for rolling shutters and blinds...

Page 12: ...tube must not present any obstacle which prevents the motor being inserted or rotating e g screw attaching the shutter to the tube If necessary remove any obstacles from the tube Insert the motor as f...

Page 13: ...13 EN D INSTALLATION Attach the anchor plate 30Nm drive kit for rolling shutters and blinds...

Page 14: ...and blinds Ensure that the end stop setting button located at the end of the motor remains accessible Where possible reattach the shutter in an intermediate position neither completely open nor comple...

Page 15: ...15 EN D INSTALLATION Thread the power supply cable as shown Ensure that it cannot become trapped in any moving parts 30Nm drive kit for rolling shutters and blinds...

Page 16: ...pped in any moving parts 3 CONNECTING THE MANAGEMENT MODULE WARNING all wiring must take place when the system is isolated circuit breaker set to OFF 3 5 M 3 5 Notes How the raising and lowering phase...

Page 17: ...17 EN D INSTALLATION 4 REMOTE CONTROL Remove the tab on the back of the remote control to connect the battery 30Nm drive kit for rolling shutters and blinds...

Page 18: ...button is difficult to access due to lack of space or proximity to moving parts use a narrow tool to safely press the button To set the end stops you will need to operate the shutter briefly If your...

Page 19: ...time for 3 seconds The LED on the remote control blinks red Then place the device to be controlled into pairing mode Refer to the device s user guide to find out how to do this Note You can pair up t...

Page 20: ...ote control with a Thombox it does not appear in the dashboard but is available in the rule creator in the Contr les Controls section You can then create rules which you can trigger using the buttons...

Page 21: ...or A force sensor to avoid any damage to the shutter The thermal safety mechanism is designed to prevent the electric shutter motor from damage when the motor is overworked This thermal safety mechani...

Page 22: ...correct wiring The thermal safety mechanism is engaged The force sensor is engaged Check the wiring Wait 15 minutes to give the thermal safety mechanism time to cool down and disengage Identify the bl...

Page 23: ...er Consumption at rated strength Maximum shutter surface Operating temperature Maximum power Assigned operating duration ARW 868 3MHz protocol ARW 868 3MHz protocol Tubular 230V AC motor epicyclic red...

Page 24: ...t is not to specification If the problem is caused by the product itself the technician will give you an RMA number so that you can return the unit to the shop Without this RMA number the shop may ref...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...is a TECHNICOLOR S A brand used under licence by Avidsen France S A S 32 rue Augustin Fresnel 37170 Chambray les Tours France...

Reviews: