background image

23

EN

H - TECHNiCAL ANd LEGAL iNFOrMATiON

30Nm drive kit 

for rolliNg shutters aNd bliNds

1 - TECHNICAL CHARACTERISTICS

Remote control

Management module

Tubular motor

Radio frequency

Radio frequency

Type

Radio range 

Radio range 

Power supply 

Operating temperature 

Power supply 

Power supply 

Rated torque 

Maximum number of turns 

Number of channels 

Operating temperature 

Speed at rated torque 

Maximum shutter weight 

Number of devices per channel 

Minimum power 

Consumption at rated strength 

Maximum shutter surface 

Operating temperature 

Maximum power 

Assigned operating duration 

ARW 868.3MHz protocol

ARW 868.3MHz protocol

Tubular 230V AC motor, epicyclic reduction gear assembly

Up to 150m in open air*

Up to 150m in open air*

230V AC 50Hz

0°C to 40°C

3V DC via a CR2032 battery

230V AC 50Hz

30Nm

22

4 groups of 3 channels

0°C to 40°C, indoor use only

15 rpm

70 kg

5

5W

0.87a

5.6m² (PVC); 9m² (aluminium); 9m² (wood)

0°C to 40°C, indoor use only

500W

4 min

*The indicated radio range refers to the open air range, i.e. no obstacles between the receiver and the 
transmitter. Any obstacle or disturbance will reduce this range.

Summary of Contents for 500014

Page 1: ...EN 30Nm drive kit for rolling shutters and blinds ref 500014 70Kg 3m www thomsonbox eu v2...

Page 2: ...08 D INSTALLATION 09 1 INSTALLING THE TUBULAR MOTOR 09 2 INSTALLING THE MANAGEMENT MODULE 16 3 CONNECTING THE MANAGEMENT MODULE 16 4 REMOTE CONTROL 17 E CONFIGURATION 18 1 PROGRAMMING 18 2 SETTING MOT...

Page 3: ...7 USING THE GROUP SELECTOR 21 8 REPLACING THE REMOTE CONTROL BATTERY 21 9 MOTOR SAFETY FEATURES 21 G FAQ 22 H TECHNICAL AND LEGAL INFORMATION 23 1 technical characteristics 23 2 warranty 24 3 help and...

Page 4: ......

Page 5: ...eplaced by an original part and nothing else Periodically check the installation for any signs of wear or damage to the shutter the mechanical parts and the mounting Do not use the device if repairs o...

Page 6: ...r tube connector ring 4 Head adaptor 1 End stop configuration button 2 Shutter tube connector ring location 3 Output shaft only driven part in the whole motor 5 Snap ring 6 Pin 7 Management module 8 R...

Page 7: ...Terminal blocks for connecting to the motor and the mains supply 30Nm drive kit for rolling shutters and blinds 4 remote control 2 4 3 5 1 6 7 1 System on indicator light 2 Channel 1 2 3 on buttons 3...

Page 8: ...ghting etc openers shutter motors garage doors etc and manage your energy use heating and electricity consumption with just a few clicks on a computer touchscreen tablet or smartphone from anywhere in...

Page 9: ...9 EN D INSTALLATION 30Nm drive kit for rolling shutters and blinds 1 INSTALLING THE TUBULAR MOTOR Remove the rolling shutter cover...

Page 10: ...e the shutter housing drive plate Remove all obstacles so that there is a flat surface Strengthen if required Note the axis of the axle that the motor will replace then place the motor anchor plate al...

Page 11: ...11 EN D INSTALLATION Align the slots on the ring with the motor collar Attach the head adaptor 30Nm drive kit for rolling shutters and blinds...

Page 12: ...tube must not present any obstacle which prevents the motor being inserted or rotating e g screw attaching the shutter to the tube If necessary remove any obstacles from the tube Insert the motor as f...

Page 13: ...13 EN D INSTALLATION Attach the anchor plate 30Nm drive kit for rolling shutters and blinds...

Page 14: ...and blinds Ensure that the end stop setting button located at the end of the motor remains accessible Where possible reattach the shutter in an intermediate position neither completely open nor comple...

Page 15: ...15 EN D INSTALLATION Thread the power supply cable as shown Ensure that it cannot become trapped in any moving parts 30Nm drive kit for rolling shutters and blinds...

Page 16: ...pped in any moving parts 3 CONNECTING THE MANAGEMENT MODULE WARNING all wiring must take place when the system is isolated circuit breaker set to OFF 3 5 M 3 5 Notes How the raising and lowering phase...

Page 17: ...17 EN D INSTALLATION 4 REMOTE CONTROL Remove the tab on the back of the remote control to connect the battery 30Nm drive kit for rolling shutters and blinds...

Page 18: ...button is difficult to access due to lack of space or proximity to moving parts use a narrow tool to safely press the button To set the end stops you will need to operate the shutter briefly If your...

Page 19: ...time for 3 seconds The LED on the remote control blinks red Then place the device to be controlled into pairing mode Refer to the device s user guide to find out how to do this Note You can pair up t...

Page 20: ...ote control with a Thombox it does not appear in the dashboard but is available in the rule creator in the Contr les Controls section You can then create rules which you can trigger using the buttons...

Page 21: ...or A force sensor to avoid any damage to the shutter The thermal safety mechanism is designed to prevent the electric shutter motor from damage when the motor is overworked This thermal safety mechani...

Page 22: ...correct wiring The thermal safety mechanism is engaged The force sensor is engaged Check the wiring Wait 15 minutes to give the thermal safety mechanism time to cool down and disengage Identify the bl...

Page 23: ...er Consumption at rated strength Maximum shutter surface Operating temperature Maximum power Assigned operating duration ARW 868 3MHz protocol ARW 868 3MHz protocol Tubular 230V AC motor epicyclic red...

Page 24: ...t is not to specification If the problem is caused by the product itself the technician will give you an RMA number so that you can return the unit to the shop Without this RMA number the shop may ref...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...is a TECHNICOLOR S A brand used under licence by Avidsen France S A S 32 rue Augustin Fresnel 37170 Chambray les Tours France...

Reviews: