MOTOR DRIVE FOR 2-PANEL GATES - CONNECT
D - BEGINNING OPERATION
2.2. Photocell alignment procedure
(optional)
The electronic card of this motorised gate is on
standby after 1 minute with no action.
On standby, the photocells no longer have
power.
• To prolong the “activation” time, press and
release one of the buttons.
When the photocells have power, a red indicator
is lit inside each one.
When the photocells are not aligned, a second
indicator light turns on in the RX photocells.
When the photocells are aligned, only one red
indicator light turns on inside the RX photocell.
• Move your hand in front of it to hide the infrared
beam. The second indicator light turns on and
off. A relay click can be heard when the status
changes.
2.3. Operating mode
This automatic gate opening mechanism has 3
operating modes.
Semi-automatic mode (mode 1) (default)
• Closed gate -> to open the gate, press and
release the gate command.
• Open gate -> to close the gate, press and
release the gate command.
While the gate is in motion, you can stop it by
pressing the (gate or pedestrian) command.
By pressing on the gate command again, the
gate swings in the opposite direction.
Automatic closing mode (mode 2)
• Closed gate: pressing and releasing the gate
command once opens the gate, which remains
open for a certain time (adjustable time, see
“Time delay”), then closes automatically.
• During the time delay, you can cancel the
automatic closure by pressing the (gate or
pedestrian) command. The gate stays open and
you must press the gate command to close the
gate.
While the gate is in motion, you can stop it by
pressing the (gate or pedestrian) command.
Collective mode (mode 3)
This mode is used for a collective access gate.
• Closed gate: pressing and releasing the gate
command once opens the gate, which remains
open for a certain time (adjustable time, see
“Time delay”), then closes automatically.
Unlike the automatic closure mode:
• If you press a command during opening, it will
not be acknowledged.
• If you press a command during the time delay,
instead of cancelling the automatic closure,
the time delay starts again at 0.
• If you press a command during closure,
the gate shuts, opens again and starts the
automatic closure time delay.
• You can only control the complete gate.
The pedestrian command does not work.
To choose the operating mode, set a value
from 1 to 3. Follow the procedure below
• Press
PROG
for 3 seconds. L0 will flash once
and L1 will turn on.
• Press
OK
and the number of red LEDs that
turn on will indicate the operating mode that
has already been set (mode 1 by default).
• To change the operating mode, use the “
–
”
and “
+
” buttons, then confirm with the
OK
button. All the LEDs turn on and off to confirm
the operation.
N.B.:
applicable regulations require the
installation of photocells for security during
automatic closing.
2.4. Time delay
The time delay is the time during which the gate
remains open before closing automatically (if
automatic closing is activated).
To adjust this value, follow the procedure
below
• Press
PROG
for 3 seconds. L0 will flash once
and L1 will turn on.