47
EN
EN
www.mythomson.com
MOTOR DRIVE FOR 2-PANEL GATES - CONNECT
• If the red LEDs all flash 3 times, this means
that the system has waited for more
than 10 seconds without receiving valid
information. Restart the programming.
• Programming a button for the Pedestrian
OPENING command:
• Press “
–
” for 3 seconds and L1 will switch on.
• Press “
+
” and L1 will switch off and L2 will
switch on.
• Press
OK
and L1 and L4 will turn on alternately.
• Within the next 10 seconds, press the remote
control button for memorisation.
• If the red LEDs all turn on for 1 second, this
means that memorisation is successful.
• If the red LEDs all flash 3 times, this means
that the system has waited for more
than 10 seconds without receiving valid
information. Restart the programming.
2.8.2. Copy programming
From a remote control that has already been
memorised, you can memorise other remote
controls (“copy” function).
For each new remote control to be
memorised, follow the procedure below
• Stand near the motor.
• Press simultaneously on both buttons at the
bottom of the remote control already in the
memory until the flashing light switches on
(around 6 seconds).
• Press any button on the new remote control.
The flashing light will flash 3 times and then
turn off.
The new remote control is now memorised
(the buttons will have the same function as the
original remote control).
2.8.3. Deleting all remote controls
To unprogramme all the remote control
buttons learnt, follow the procedure below
• Press “
–
” for 3 seconds and L1 will switch on.
• Press “
+
” twice and L1 will turn off and L3 will
turn on.
• Press
OK
. The 4 red LEDs will turn on.
• Press
OK
for 3 seconds. All the LEDs will turn
off and turn on to confirm the operation.
3. ADVANCED SETTINGS
Certain adjustments may be necessary in the
event of a problem or for specific use of the
electronic card. There are two additional menus
with basic settings.
réglages simples
MOD
E
TEMPORISATIO
N
FORC
E
VITESSE
réglages simples
Accélération
Mode Photocellules
Type de portail
Tolérance butée
réglages simples
Décalage fermetur
e
Temps préclignotement
PROG 3s
PROG 3s
PROG 3s
PROG
PROG
PROG
MENU
1
MENU 0
MENU 2
MENU
3