MOTOR DRIVE FOR 2-PANEL GATES - CONNECT
EN
48
www.mythomson.com
3.1. Access to advanced settings
(MENUS 2 and 3)
To access menus 2 and 3, follow the
procedure below
• Press
PROG
for 3 seconds. L0 will flash once,
L1 will turn on and you will be in
menu 1 (basic
settings)
.
• Press
PROG
again for 3 seconds. L0 will flash
twice, L1 will turn on and you will be in
menu 2
(advanced settings).
• Press
PROG
again for 3 seconds. L0 will flash
three times, L1 will turn on and you will be in
menu 3 (advanced settings).
3.2. Advanced settings menu (MENU 2)
Accélération
OK
PROG
Réglage accélération
+ : augmente l’accération
– : diminue l’accélération
OK
MENU 0
réglable de 0 à 4
Tolérance butée
OK
PROG
Réglage tolérance
+ : augmente la tolérance
– : diminue la tolérance
OK
MENU 0
réglable de 0 à 4
* cette modification nécessite de refaire un auto-apprentissage
Type de portail
Mode photocellules
OK
PROG
Type de portail
– et + pour régler la valeur
OK
MENU 0
OK
PROG
Mode photocellules
– et + pour régler la valeur
OK
MENU 0
0 : inactives en début d’ouverture
(par défaut)
1 : actives en début d’ouverture
0 : portail à 2 battants (par
défaut)
1 : portail à 1 battant (portillon)
–
+
+
–
+
–
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
Enregistre réglage*
L1
L2
L3
L4
Enregistre réglage
L1
L2
L3
L4
Enregistre réglage*
L1
L2
L3
L4
Enregistre réglage*
L1
L2
L3
L4
This change requires a new self-learning
procedure.
3.2.1. Acceleration
The acceleration at the start of the panel
opening process can be adjusted from a level of
0 to 4. The higher this value, the more time the
gate will take to open. The default level is 3, at
which the gate takes about 4 seconds to open.
It may be useful to reduce the acceleration for
a softer start.
To adjust the acceleration, follow the
procedure below
• Press
PROG
for 3 seconds. L0 will flash once
and L1 will turn on.
• Press
PROG
, for 3 seconds. L0 will flash twice.
• Press
OK
and the number of LEDs that turn on
will indicate the set value.
• Use the “
–
” and “
+
” buttons to change this
value.
• Press
OK
to confirm this value. All the LEDs will
turn on and off to confirm the operation.
D - BEGINNING OPERATION