49
EN
EN
www.mythomson.com
MOTOR DRIVE FOR 2-PANEL GATES - CONNECT
D - BEGINNING OPERATION
N.B.
If the acceleration setting is changed, self-
learning must be repeated.
3.2.2. Photocell mode
The photocells are active when the panels close
because they are placed between the posts (pair
1) to secure the passage between panels.
The installation of a second set of photocells is
useful to completely protect the gate movement
area during closing and opening:
Inner side of the property
view from above
pair 2
pair 1
RX1
RX2
TX1
TX2
In that case, the system must verify that its
infrared beam is not obstructed before starting
to open the panels. But by default, photocells are
only tested during closure.
To activate or deactivate photocells at the
beginning of the opening process, follow the
procedure below
• Press
PROG
for 3 seconds. L0 will flash once
and L1 will turn on.
• Press
PROG
for 3 seconds. L0 will flash twice.
• Press “
+
” once. L2 will turn on instead of L1.
• Press
OK
.
• If L1 is off, the photocells are inactive at the
beginning of the opening process. Press “
+
” to
activate them, then
OK
to confirm. All LEDs will
turn on and off to confirm the operation.
• If L1 is on, the photocells are active at the
beginning of the opening process. Press “–” to
deactivate them, then
OK
to confirm. All LEDs
will turn on and off to confirm the operation.
3.2.3. Type of gate
To operate the electronic card on a single-panel
gate, this setting must be changed. By default,
this value is set to 0 (2-panel gate mode).
In addition, the motor output that remains active
in side gate mode is M1 (not to be confused with
the pedestrian passage function).
To activate or deactivate this function,
follow the procedure below
• Press
PROG
for 3 seconds. L0 will flash once
and L1 will turn on.
• Press
PROG
for 3 seconds. L0 will flash twice.
• Press “
+
” twice and L3 will switch on instead of
L1.
• Press
OK
.
• If L1 is off, gate mode is activated. Press “
+
” to
activate side gate mode, then
OK
to confirm.
All LEDs will turn on and off to confirm the
operation.
• If L1 is on, side gate mode is activated. Press
“
–
” to activate gate mode, then
OK
to confirm.
All LEDs will turn on and off to confirm the
operation.
Self-learning is required if this setting is
changed.
3.2.4. Stop tolerance
During self-learning, the system learns the
path of each panel to determine when a panel
stops if it has reached a stop or an obstacle. In
fact, during a movement, if more than a certain
percentage of the path remains to be completed
by the panel but it comes under strain, the system
considers it to be pushing against an obstacle.
If the panel comes under strain when less than
such percentage remains to be completed, the
system considers that the panel has reached its
stop. By default, this percentage is 3%.