MOTOR DRIVE FOR 2-PANEL GATES - CONNECT
EN
50
www.mythomson.com
However, the accuracy of the system depends
on many parameters, such as temperature,
motor quality, the type of motor cables and the
flexibility and weight of the gate. Depending on
these parameters, the path measuring system
may not be accurate enough to operate with
this default tolerance. In this case, the system
can trigger obstacle detection when the panels
reach their normal stop. If this occurs (and after
confirming that the opening and closing stops
are stable), the obstacle detection tolerance
must be increased.
To adjust this tolerance level, follow the
procedure below
• Press
PROG
for 3 seconds. L0 will flash once
and L1 will turn on.
• Press
PROG
for 3 seconds. L0 will flash twice.
• Press “
+
” three times. L3 will turn on instead
of L1.
• Press
OK
. The number of LEDs that turn on will
indicate the set value.
• Use the “
–
” and “
+
” buttons to change
this value. The higher the value, the higher
the tolerance level (“lower risk of obstacle
detection at the stop”).
• Press
OK
to confirm this value. All the LEDs will
turn on and off to confirm the operation.
Self-learning is required if this setting is
changed.
3.3. - Advanced settings menu (MENU 3)
Décalage fermeture
OK
PROG
Réglage temps
+ : augmente le temps
– : diminue le temps
OK
MENU 0
0 : 2.5 sec (par defaut)
1 : 3 sec
2 : 3.5 sec
3 : 4 sec
4 : 4.5 sec
Temps préclignotement
OK
PROG
Temps préclignotement
OK
MENU 0
– et + pour régler la valeur
0 : 1 sec (par défaut)
1 : 3 sec
–
+
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
Enregistre réglage
L1
L2
L3
L4
Enregistre réglage
L1
L2
L3
L4
3.3.1. Panel movement time difference
In general, on closing, one gate panel closes over
the other. This panel is controlled by the motor
connected to output M1 of the electronic card.
To ensure that the panels close in the correct
order, the system arranges for the panel of
motor M2 to come to a stop 2.5 seconds before
the panel of motor M1. If the gate is solid and
exposed to the wind, panel M2 may be stopped
by the wind and panel M1 may be helped by the
wind on closing. In this case, panel M1 may catch
up to panel M2 and the panels may close in the
wrong order.
If this occurs, the time interval between the panel
movements during closure may be increased.
To adjust this time interval, follow the
procedure below
• Press
PROG
for 3 seconds. L0 will flash once
and L1 will turn on.
• Press
PROG
for 3 seconds. L0 will flash twice.
D - BEGINNING OPERATION