• Press
PROG
for 3 seconds. L0 will flash 3
times.
• Press
OK
. The number of LEDs that turn on will
indicate the set value.
• Use the “
–
” and “
+
” buttons to change this
value (see table below).
• Press
OK
to confirm this value. All the LEDs will
turn on and off to confirm the operation.
L1
L2
L3
L4
2.5 s (par défaut)
L1
L2
L3
L4
3 s
L1
L2
L3
L4
3.5 s
L1
L2
L3
L4
4 s
L1
L2
L3
L4
4.5 s
Note: During opening, there is also a time
interval between the panel movements, but
this time interval is fixed and is equal to 2.5
seconds.
3.3.2 - Pre-flashing time
The flashing light is an important safety
component
. It starts when a command to set the
gate in motion is received by the electronic card.
The gate is set in motion around one second after
a command is received.
In certain use cases, it is better that the time
between receiving a motion command and the
start of the manoeuvre is longer. It is possible to
increase this time to 3 seconds.
To set the pre-flashing time, follow the
procedure below
• Press
PROG
for 3 seconds. L0 will flash once
and L1 will turn on.
• Press
PROG
for 3 seconds. L0 will flash twice.
• Press
PROG
for 3 seconds. L0 will flash 3 times.
• Press “
+
” once. L2 will turn on instead of L1.
• Press
OK
.
• If L1 is off, the time is 1 second. Press “
+
” to
increase it to 3 seconds, then
OK
to confirm.
All LEDs will turn on and off to confirm the
operation.
• If L1 is on, the time is 3 seconds. Press “
–
” to
reduce it to 1 second, then
OK
to confirm.
All LEDs will turn on and off to confirm the
operation.
D - BEGINNING OPERATION