41
PRELIMINAR
Y
C
ONVERGENCE
E
RROR
C
ODES
There are a number of error codes linked with specific convergence failures. Remember that
“Sensor Calibration” and “Autoconvergence” are two separate functions of convergence. Sensor
Calibration is done in two parts. Setting luma levels is done with convergence essentially “zeroed”
such that it has little effect on the sensor calibration routine at that point. Location of the sensors
is done by loading the default EEPROM values into the convergence micro DAC’s, then finding
the 8 screen sensors. The figure below shows where those sensors are physically located and how
they are numbered.
1
2
3
4
5
6
7
8
The sensor calibration software projects a small block of video in each color and at each sensor
location. It first moves the block in from the top, then bottom, then each side until the sensor
“sees” the light. At the moment the light is “seen” the DAC reading is taken.
Sensor
Video Block
Video Block
Video Block
Video Block
By averaging the combined DAC values of these blocks, the sensor may be precisely located.
The important point to remember is the error codes that are logged if a sensor is not located.
The error codes are located in the “Event History” menu of the Field Service Menu.