background image

User Manual

H-HDCOAX-1/2/4/6/8 

Modulator 

Summary of Contents for H-HDCOAX-1

Page 1: ...User Manual H HDCOAX 1 2 4 6 8 Modulator ...

Page 2: ... in any form without the written permission of Thor Broadcast The contents of this document are subject to revision without notice due to continued progress in methodology design and manufacturing Thor shall have no liability for any error or damage of any kind resulting from the use of this document Copy Warning This document includes some confidential information Its usage is limited to the owne...

Page 3: ...CHAPTER 2 INSTALLATION GUIDE 5 2 1 GENERAL PRECAUTIONS 5 2 2 POWER PRECAUTIONS 5 2 3 DEVICE S INSTALLATION FLOW CHART ILLUSTRATED AS FOLLOWING 5 2 4 ENVIRONMENT REQUIREMENT 6 2 5 GROUNDING REQUIREMENT 7 CHAPTER 3 OPERATION 8 3 1 LCD MENU STRUCTURE 8 3 2 GENERAL SETTINGS 10 CHAPTER 4 WEB NMS OPERATION 15 4 1 LOGIN 15 4 2 OPERATION 16 CHAPTER 5 TROUBLESHOOTING 22 CHAPTER 6 PACKING LIST 23 ...

Page 4: ...ellite receivers closed circuit television cameras Blu ray players and antenna off air Its output signals are to be received by TVs STB etc with the correlated standard the unit is set to encode with ATSC DVB T DVB C The 4 ADHD units are widely used everywhere such as the mall market hall theatre hotels restaurants stadiums race tracks ampitheatres and etc for advertising monitoring training and e...

Page 5: ... 6M DVB T Modulator Section Standard DVB T COFDM Bandwidth 2M 3M 4M 5M 6M 7M 8M Constellation QPSK 16QAM 64QAM Code rate 1 2 2 3 3 4 5 6 7 8 Guard Interval 1 32 1 16 1 8 1 4 Transmission Mode 2K 8K MER 35dB RF frequency 100 1000MHz 1KHz step RF output level 63 16dBm 44 91 dBµV 1dB step ISDB Modulator Section Standard ARIB STD B31 Constellation QPSK 16QAM 64QAM Guard Interval 1 32 1 16 1 8 1 4 Tran...

Page 6: ... Power Switch LCD Screen Power and Alarm Indicators Directional Keys up down left right Enter Key Menu Key Lock Key Rear Panel Illustration 1 2 3 4 5 HDMI CC Input Port NMS Ethernet Port RF Output L R Audio input Stereo or Mono SPDF port Not applicable at present ASI input port ASI Output port 1 2 Power Switch Power supply Slot RF out port ...

Page 7: ...H HDCOAX 1 2 4 6 8 SatelliteDish com 954 941 8883 1 5 Application Drawing ...

Page 8: ...y After installation securely stow away all loose cables external antenna and others 2 2 Power precautions Be careful when connecting a power source to the device Do not operate in wet or damp areas Make sure the extension cable is in good condition Make sure the power switch is off before you start to install the device 2 3 Device s Installation Flow Chart Illustrated as following Connecting Grou...

Page 9: ... current limiting resistance 1M Floor bearing should be greater than 450Kg Environment Temperature 5 40 sustainable 0 45 short time installing air conditioning is recommended Relative Humidity 20 80 sustainable 10 90 short time Pressure 86 105KPa Door Window Installing rubber strip for sealing door gaps and dual level glasses for window Fire Protection Fire alarm system and extinguisher Power Devi...

Page 10: ... of them make sure the device is grounded when installing anywhere Always use copper wire When applied correctly the ground must be wrapped well to ensure maximum conduction so it can reduce any high frequencies The copper ground wire should also be as short and thick as possible Installer must make sure that the two ends of the ground are well conducted and have appropriate anti rust properties I...

Page 11: ...ng up down when parameter is inactivated LOCK Lock the screen cancel the lock state After pressing the lock key the LCD will display the current configuring state 3 1 LCD Menu Structure Switch On LCN Version Num Private Data 1 TS Config Country Code Network ID LCN Mode Channel List ID 1 1 Channel 1 1 2 Channel 2 1 3 Channel 3 1 4 Channel 4 Channel List Name Same Contents as Channel1 Major Channel ...

Page 12: ...1 Channel 1 3 2 Channel 2 3 3 Channel 3 3 4 Channel 4 Symbol Rate Constellation Freq Level Standard Bandwidth Guard Interval Freq Level FFT Code Rate Constellation Level Freq FFT Code Rate Freq Level Guard Interval Constellaselect Time Interleaving 4 Network 4 1 IP Address 4 2 Subnet Mask 4 3 Gateway 4 4 MAC Address 5 System Setting 5 1 Save 5 2 Restore 5 3 Factory set 6 Soft Version CPU Version B...

Page 13: ...on carriers Under this menu you can enter the corresponding channels to set your relevant parameters Select each channel and set your settings as you see fit After pressing the enter key the LCD will display the following pages Channel 1 2 3 4 The HDCOAX 4 also has can output any standard DVB C DVB T ATSC or ISDB T modulation Select different modulation modes under the modulate menu the TS paramet...

Page 14: ...CN Channel List ID Version Num Country Code Private Data Channel List Name Network ID LCN Mode LCN Channel List ID Version Num Country Code Private Data Channel List Name Major Channel Minor Channel Source ID Channel TSID Network ID Version Num Key ID Service ID Area Code Trans Type Info TS Name ...

Page 15: ... as an example Press the enter key and the submenu will show as follows on the LCD 3 2 3 Modulate The HDCOAX 4 has up to 4 RF carriers enter the corresponding channel to set the relevant RF output parameters 2 1 Channel 1 2 2 Channel 2 2 3 Channel 3 2 4 Channel 4 2 1 Channel 1 Bit Rate Audio format GOP Latency TS ID ON ID CC Switch Program Number Program Provider Program Name PMT PID Video PID Aud...

Page 16: ...enus DVB C DVB T ATSC ISDB T 3 2 4 Network Setting The Network Setting has four submenus as shown below IP Address 192 168 000 136 Freq Level Symbol Rate Standard Constellation Freq Level Bandwidth FFT Guard Interval Code Rate Constellation Freq Level FFT Guard Interval Code Rate Constellaselect Time Interleaving Freq Level ...

Page 17: ...is menu choose yes to restore the device the last saved configuration Factory Set Choose yes to restore the device into factory s default configuration 3 2 6 Soft Version Check the CPU Board and Web version of this modulator under this submenu Subnet Mask 255 255 255 000 Gateway 192 168 000 001 MAC Address xx xx xx xx xx xx CPU Board Web Version XX XX XX Restore YES NO Saving Config YES NO Factory...

Page 18: ... 0 136 We can modify the IP through the front panel Connect the pc and the device with net cable and use ping command to confirm they are on the same network segment E G the PC IP address is 192 168 99 252 we then change the device IP to 192 168 99 xxx xxx can be 0 to 255 except 252 to avoid IP conflict Use any web browser to connect the device with the PC by inputting the Encoder Modulator s IP a...

Page 19: ... Clicking TS Config users can configure 4 channels of the output TS users select different modulating modes the TS config parameters will be different Figure 3 Click any item here to enter the corresponding interface to check information or set the parameters Click here to check the version information Click here to check the encode and modulate version information DVB C Modulation ...

Page 20: ...H HDCOAX 1 2 4 6 8 SatelliteDish com 954 941 8883 Figure 3 DVB T Modulation ATSC Modulation ISDB T Modulation ...

Page 21: ...gram from the 4 HDMI encoded channels Figure 4 Parameters Modulate Click Modulate it displays the interface where users can configure the modulating parameters Figure 5 4 encoded channels AC3 AAC MPEG1 Layer2 Audio encoding format Select modulate mode each channel supports five modulation modes DVB C DVB T ATSC T ISDB T ...

Page 22: ... 4 6 8 SatelliteDish com 954 941 8883 Click Channel1 2 3 4 it displays the interface where you can configure the modulating parameters Channel 1 DVB C modulation Channel 2 DVB T modulation Channel 3 ATSC modulation ...

Page 23: ...8883 Channel 4 ISDB T modulation Figure 6 System Network Click Network it displays the where to set network parameters Figure 7 System Password Click Password it displays the screen where to set login account and password for the web NMS Figure 8 ...

Page 24: ... Firmware it displays the screen where to update the firmware on this HDCOAX 4 Figure 9 System Save Restore Factory Set Backup Load Click Save Restore Factory Set Backup Load it displays the screen where to Save Restore Factory Set Backup Load your configurations Figure 10 ...

Page 25: ...plenty of ventilation for the heat sink on the rear panel and other heat sink bores if necessary Checking the AC input within the power supply and ensure it is working the connection is correctly installed before switching on device Checking the RF output levels to stay within a tolerable range if it is necessary Checking all signal cables have been properly connected Frequently switching on off d...

Page 26: ... 4 6 8 SatelliteDish com 954 941 8883 Chapter 6 Packing List THOR BROADCAST HDCOAX 4 1 PC User s Manual 1 PC HDMI Cables 1 2 4 6 8 PCS Power Cord 1 PC For Further Tech Support 1 954 941 8881 Today SatelliteDish com ...

Page 27: ...H HDCOAX 1 2 4 6 8 SatelliteDish com 954 941 8883 ...

Reviews: