WARNING:
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.
1.
Check all gas connections for leakages.
2.
Check the following functions in accordance with the operating instructions
•
Light the Pilot Burner.
•
Light the Main Burner.
•
Check the ‘Low Fire’ burner operation.
•
Check the ‘High Fire’ Burner operation.
•
Ensure that all the controls operate correctly.
•
Ensure that the operating pressure remains correc
t.
3.
Ensure any adjustments done to components that have the adjustments / settings sealed (e.g. paint sealed)
are re-sealed.
NOTE:
If for some reason it is not possible to get the appliance to operate correctly, shut off the gas supply and
contact the supplier of this appliance.
●
Gas Specifications
Natural Gas
LPG
Category
I2H
I3B/P, I3+
Main Burner Orifice
44# (
¢
2.18mm)
53# (
¢
1.51mm)
Pilot Burner Injector
¢
0.45 mm
¢
0.25 mm
Operating Pressure
20 mbar
28-30 mbar
Supply Pressure
20 mbar
28-30 mbar
Note:
The burner operating pressure is to be measured at the gas control valve outlet
test point with one Main burner operating at ‘High’ setting. The operating pressure
is ex-factory set
CAUTION:
Please replace the corresponding warning label that shows the gas type operated when the
qualified person will convert to another gas in order not to cause death or injury or damage.
Orifice 53#
Use to LPG
Orifice 44#
Use to Natural Gas