Specifications
3.1
3.1
3.1
3.1
ASI Interface
Input port
:
2 routs DVB ASI port
Connector
:
BNC
Impedance
:
75
Ω
TS standard
:
ISO13818-1
Input effective bit rate
:
max 214Mbps
(
each route
)
TS packet format
:
188/204bytes
(
auto recognition
)
TS input mode
:
CBR /BURST/VBR
3.2
3.2
3.2
3.2
Network port
There are two network ports on the H-1ASI-IP-B.
Data Port: The RJ-45 Port labeled “Data” is the transport port for the
encapsulated ASI stream. This port carries the primary IP address for the device, and
is the only port that needs to be connected for the device to function. It is important to
note that the Data port IP address does not support the “ping” function. It is also
important to note that when making changes to the IP configurations either via front
panel or NMS it is important to use the “Save Config” option on the top menu when on
the front panel, or click the “Save Config” button in the software when using NMS.
Ethernet Port: This port is for network management via the Network
Management Software. It is not essential for this port to be connected for proper
functioning of the device. However the Network Management Software is the most
effective method for setting the devices IP address. If problems arise while attempting
to set the device IP with the front panel please use the network management software.