95
Charger not charging even though CHG LED is on steady and the unit says
“Charging”:
Full charge rates are not obtained in Charging mode, only after this mode
changes to Bulk Charging, Absorb Charging, or Float Charging modes.
Charger not charging even though CHG LED is on steady and the
unit says “Bulk Charging” (or “Absorb Charging”):
Check the 01B DC Amps and the 01A DC Volts meters on the display, it should
be 80% or more of rated charge current if the battery voltage is under 14.0
VDC (28.0 VDC on 24-volt models or 48.0 VDC for 48-volt models). If not, check
the 03C Max Charge Rate setting and verify the setting is 80% or greater. Still
low charge rate? Check the Shore Amps setting to verify. If no AC loads are being
‘passed thru’ the inverter, the Shore Amps setting must be 15 amps (25 amps for
3kW unit) or greater, to receive full charge rate.
Charger says “Float Charging” not “Bulk Charging” when the AC
is first plugged in:
Check the 01A DC Volts meter on the display, if the battery is over 13.0 VDC
(26.0 VDC for 24-volt models or 52.0 VDC for 48-volt models) then the battery
was already charged, and the charger automatically goes to Float Charging to
keep from overcharging the batteries.
Charge amps are lower than expected, or is 0 amps DC:
Measure input AC voltage and increase if the input voltage is under 90 VAC. The
charge rate is reduced to try and keep the input voltage above 90 VAC; also check
the Shore Max (p. 6) and 03C Max Charge Rate settings to determine if the
current is being limited.
Charger output voltage is higher than expected:
Check the Battery Temperature Sensor (BTS) temperature. If the BTS is installed,
the charge voltage settings will increase if the temperature around the BTS is
below 77° F (25° C), and will decrease if the temperature around the BTS is
higher than 77° F (25° C).
Performing an
Inverter Reset
1. Press and hold the Power ON/OFF pushbutton (see Figure 6-1) for approximately
15 seconds until the Charging/Inverting Status LED comes on and flashes rapidly.
Once the rapid flashing has begun, release the Power ON/OFF pushbutton. The
Status LED will go off after the pushbutton is released.
2. After the inverter reset is completed, press the ON/OFF pushbutton to turn the
inverter ON.
Electrical Systems
Summary of Contents for Palazzo 2015
Page 1: ......
Page 3: ...This page intentionally left blank...
Page 17: ...16 Warranty...
Page 25: ...24...
Page 37: ...36...
Page 41: ...40 Chassis...
Page 45: ...44...
Page 52: ...51...
Page 54: ...53 Controls and Operations Turn on power Retracting the jacks Press auto level touch pad...
Page 56: ...55 Controls and Operations Hydraulic Pump Function Wiring...
Page 75: ...74...
Page 76: ...75...
Page 77: ...76...
Page 78: ...77...
Page 79: ...78...
Page 87: ...86 Heating and Air Conditioning...
Page 105: ...104...
Page 133: ...132...
Page 138: ...137...
Page 141: ...140 Date Service Preformed Mileage Date Service Preformed Mileage Maintenance Schedule...
Page 142: ...141 Maintenance Schedule Date Service Preformed Mileage Date Service Preformed Mileage...
Page 145: ...144 Notes...
Page 146: ...145 Notes...
Page 150: ......