Chapter 5  Maintaining the LSK-GG 

There are no serviceable parts in LSK-GG. If you suspect a problem with the LSK-GG, please contact our nearest 

office for assistance from an applications engineer (see 

Chapter 12 Thorlabs Worldwide Contacts 

for details). 

5.1.  Cleaning 

WARNING 

Disconnect the power supply before cleaning the unit to prevent any injuries. 

 

CAUTION 

DO NOT expose the unit to spray, liquids, or solvent. This may damage the unit. DO NOT allow 

spilled fluid to enter the internal mechanism. If spillage does occur, clean up immediately using an 

absorbent tissue. 

To clean the Controller Box and Scan Head: 

  Use a damp lint-free cloth to wipe the outer surface of the unit. 

  Use Compressed Air to remove the dust particles on the mirrors. 

CAUTION 

DO NOT touch the surface of the Galvo mirrors with fingers or tools to clean the mirrors. 

5.2.  Troubleshooting 

Problem 

Solution 

X FAULT and/or Y FAULT LED turns on 

  Check all cable connections. 

  Make sure the Scan Head is free from any obstruction. 

  Unplug and replug the power supply. 

  Scanner  has  exceeded  the  maximum  recommended 

mechanical/electrical  range.  There  are  internal 

mechanical stops within the scanner that prevent it from 

spinning  a  full  360

,  however  during  a  fault  state,  the 

current must be shut off before the rotor reaches these 

internal stops.  

Please contact Thorlabs Technical Support for assistance. 

CAUTION 

DO NOT let the system stay in this over-position 

indefinitely. This may damge the scanner. 

 

 

!

!

!

!

!

!

!

!

Summary of Contents for LSK-GG

Page 1: ...LSK GG Laser Scanning Kit Galvo Galvo Scan Head User Guide...

Page 2: ...t The software maybe used or copied onlyin accordance with the terms of those agreements No part of this publication maybe reproduced stored in a retrieval system or transmittedin any form or any mean...

Page 3: ...intaining the LSK GG 7 5 1 Cleaning 7 5 2 Troubleshooting 7 Replacing the Fuse 8 Chapter 6 Specifications 9 6 1 General Specifications 9 6 2 Galvo Mirror Specifications 9 6 3 Fuse Specifications 10 6...

Page 4: ...ption Direct Current Alternating Current Both Direct and Alternating Current Earth Ground Terminal Protective Conductor Terminal Frame or Chassis Terminal Equipotentiality On Supply Off Supply In Posi...

Page 5: ...ot specified by Thorlabs the protection provided by the equipment may be impaired CAUTION DO NOT operate in a wet damp or explosive environment WARNING DO NOT put your fingers inside the ports of the...

Page 6: ...elded DB 25 connector cable connects the Scan Head to the Controller The front panel provides the interface to control the galvo scanners and monitor their behavior The analog control signals from the...

Page 7: ...LSK GG Chapter 3 Description Page 4 TTN118193 D02 Figure 2 Galvo Galvo Controller Back Panel Ground Connector Fuse Holder Power Input Power Switch...

Page 8: ...ce laser safe WARNING DO NOT switch on the laser while installing the Laser Scanning Kit This may cause injury due to laser radiation Make sure the laser source is off 1 Place the unit on a dry level...

Page 9: ...ntered The FAULT LEDs may turn on for few seconds This is normal as the scanner is ramping up 8 Align your light source to the Input port the one with the smaller diameter aperture of the Scan Head 9...

Page 10: ...x and Scan Head Use a damp lint free cloth to wipe the outer surface of the unit Use Compressed Air to remove the dust particles on the mirrors CAUTION DO NOT touch the surface of the Galvo mirrors wi...

Page 11: ...power cord from the Controller 2 Use a screwdriver to pop the fuse holder from the Controller 3 Check to see if the fuse is blown If you see a black or brown smudges on the fuse glass or a clearly br...

Page 12: ...ace Quality 60 40 Scratch Dig Average Reflectance 350 450 nm 70 450 550 nm 90 550 650 nm 92 5 650 1080 nm 95 1080 7000 nm 97 Front Surface Flatness 633 nm 4 X Mirror Clear Aperture 6 22 mm x 4 0 mm El...

Page 13: ...nse Time Slow Mounting Type Holder Breaking Capacity Rated Voltage 100 A Operating Temperature 55 125 C DC Cold Resistance 0 043 6 4 Choosing a Scanner Lens Figure 3 Mirror Distance Specification Inpu...

Page 14: ...2 k output impedance 28 Y Velocity Voltage signal is proportional to the velocity of the scanner 2 k output impedance 30 X Position OUT Position Out signal 2 k output impedance 4 V 38 Y Fault Pulled d...

Page 15: ...Alignment Pins 4 Places 3 35 85 1 mm 3 06 77 8 mm 3 14 79 8 mm 0 15 3 8 mm 0 20 5 1 mm 0 85 21 6 mm 2 00 50 8 mm 3 65 92 7 mm 8 32 Locking Setscrew 5 64 2 mm Hex 2 Places Internal SM1 1 035 40 Threads...

Page 16: ...1 00 25 4 mm Typical 1 00 25 4 mm 1 06 26 8 mm 1 00 25 4 mm 1 18 30 0 mm Typical 2 08 52 8 mm 3 84 97 5 mm 0 50 12 7 mm Typical 0 49 12 5 mm 0 23 5 8 mm 0 56 14 3 mm 1 70 43 2 mm 3 Places 6 mm Bore f...

Page 17: ...LSK GG Chapter 8 Mechanical Drawing Page 14 TTN118193 D02 Figure 7 Mechanical Drawing of LSK GG Controller Front View Back View 3 12 79 2 mm 2 80 71 1 mm 11 81 299 9 mm 7 87 199 8 mm 12 47 316 7 mm...

Page 18: ...LSK GG Chapter 9 Certifications and Compliance Rev A November 11 2016 Page 15 Chapter 9 Certifications and Compliance...

Page 19: ...ranty Thorlabs warrants that all products sold will be free from defects in material and workmanship and will conform to the published specifications under normal use when correctly installed and main...

Page 20: ...abs products such as Pure OEM products that means assemblies to be built into a unit by the user e g OEM laser driver cards Components Mechanics and optics Left over parts of units disassembled by the...

Page 21: ...da and South America Thorlabs Inc sales thorlabs com techsupport thorlabs com Europe Thorlabs GmbH europe thorlabs com France Thorlabs SAS sales fr thorlabs com Japan Thorlabs Japan Inc sales thorlabs...

Page 22: ...www thorlabs com...

Reviews: