HA0263T Rev E May 2017 

Chapter 4

4.2

Maintenance

The product is maintenance free. If any problems occur, the user should contact the

local Thorlabs tech support for more information.

4.3

Transportation

Note

The MOTOR DRIVE connectors for each channel/axis contain an 

EEPROM, which stores the factory default settings for the set up 

parameters. When the stage is connected, these settings are loaded into 
the controller on start up, and are tuned for loads up to the 1.0 kg (2.2 lb) 

maximum, at speeds up to 250 mm/s.

However, depending on the load being driven and the speed/duty cycle of 

the particular application, it may be necessary to further optimize the 

Position PID loop settings. 

If problems are encountered (e.g. stability of the closed loop position 

control, lost motion or incomplete moves) the position loop PID 

parameters should be adjusted to tune the stage for the given application. 

Normally, only minor adjustment of the Proportional, Integral and 

Derivative parameters should be necessary, and some trial and error will 

be required before the ideal settings for a specific application are 

achieved. In cases where further adjustment of the control loop 

parameters is required, the following guidelines are provided in order to 

assist in the tuning process.

Position PID Settings Summary

Stage overshoots the intended position

 - reduce the integral term, and 

increase the derivative and proportional terms.

Stage fails to attain final position

 - increase the integral and proportional 

terms.

Motion is unstable

 - reduce the proportional and integral terms, increase 

the derivative term.

Stage sounds noisy

 - reduce the derivative term.

Please see the handbook supplied with the controller, for more 
information on changing these settings

Caution

When packing the unit for shipping, use the original packing. If this is not 
available, use a strong box and surround the unit with at least 100 mm of 
shock absorbent material.

Summary of Contents for MLS203 Series

Page 1: ...MLS203 1 Fast XY Scanning Stage User Guide Original Instructions...

Page 2: ...ions 8 3 4 Dimensions 9 3 4 1 MLS203 1 Dimensions 9 Chapter 4 Operation 10 4 1 General 10 4 2 Maintenance 12 4 3 Transportation 12 Chapter 5 Specification 13 Chapter 6 Spares and Accessories 14 6 1 Pa...

Page 3: ...when there is a risk of injury from electrical shock Warning Given when there is a risk of injury to users Caution Given when there is a risk of damage to the product Note Clarification of an instruc...

Page 4: ...0 25 m at speeds up to 250 mm s The high quality construction uses high rigidity precision linear bearings commercial grade limit switches and powerful brushless linear DC servo motors In addition th...

Page 5: ...5 MLS203 Series XY Scanning Stage Fig 2 1 MLS203 stage with MLS203P1 well plate adapter and 96 hole well plate mounted on a microscope...

Page 6: ...e fitted as necessary for more details see the instructions for fitting the attachment brackets When mounting the stage close to other equipment ensure that the travel of the moving platform is not ob...

Page 7: ...1 Offer up the finger guards to the stage as shown below and secure using the M3 x 16 bolts supplied Fig 3 1 Fitting the finger guards 3 2 3 Mounting To Microscope The stage can be mounted to select...

Page 8: ...ct channel Fig 3 2 Electrical connections Pin out information for the motor drive and encoder feedback connectors on the motor flying leads is detailed below Fig 3 3 Motor Drive and Feedback Flying Le...

Page 9: ...0mm 8 43in 130 5mm 5 14in 125 0mm 4 92in 120 3mm 4 74in 58 5mm 2 30in 20 5mm 0 81in M3X0 5TAPPED HOLE 4 PLACES M3X0 5TAPPED HOLE FOR MOUNTING MLS203P1 5 ACCESSORY PLATES 4 PLACES OBJECTIVE CENTRE AND...

Page 10: ...the Home button on each GUI pa nel When homing is complete the Channel Enable LEDs stop flashing Caution The MLS203 stages is designed to be driven by the Thorlabs BBD20x or RBD201 Brushless DC Motor...

Page 11: ...d as a result the position readout becomes incorrect This renders normal operation impossible because phase commutation of the motor is also based on the encoder reading When the stage is controlled b...

Page 12: ...e stage for the given application Normally only minor adjustment of the Proportional Integral and Derivative parameters should be necessary and some trial and error will be required before the ideal s...

Page 13: ...Brushless DC Linear Motor Dimensions Mid Travel 10 24 x 9 06 x 1 22 260 0 mm x 230 0 mm x 31 1 mm Weight with cables 7 0 lbs 3 2 kg Note The default tuning parameters can be changed to optimise settli...

Page 14: ...has be en designed to provid e flexible options of sample types traditional slides petri dishes or well plates as well as uniquely shaped sample holders for biofilms microfluidic studies and live sam...

Page 15: ...harmful interference in which case the user will be required to correct the interference at his own expense Changes or modifications not expressly approved by the company could void the user s author...

Page 16: ...er information 7 2 2 Waste treatment on your own responsibility If you do not return an end of life unit to the company you must hand it to a company specialized in waste recovery Do not dispose of th...

Page 17: ...17 MLS203 Series XY Scanning Stage 7 3 CE Certificates...

Page 18: ...18 HA0263T Rev E May 2017 Chapter 7...

Page 19: ...ce Thorlabs SAS 109 rue des C tes 78600 Maisons Laffitte France Tel 33 0 970 444 844 Fax 33 0 811 381 748 www thorlabs de email sales fr thorlabs com Scandinavia Thorlabs Sweden AB Bergfotsgatan 7 431...

Page 20: ...Ltd Saint Thomas Place Ely Cambridgeshire CB7 4EX UK Tel 44 0 1353 654440 Fax 44 0 1353 654444 www thorlabs com Thorlabs Inc 56 Sparta Ave Newton NJ07860 USA Tel 1 973 579 7227 Fax 1 973 300 3600 www...

Reviews: