3-3
As a guide-line, please note the equipment fuse location given in
Table 12.
Equipment
Location
Fuse size
TT-3020C Capsat
Transceiver incl.
Antenna.
Externally accessed,
located on the rear
panel.
12A T.
TT-3606E Message
Terminal
Internal automatic
recovering poly fuse
TT-3042C Remote
Alarm/Distress box
No fuse
TT-3042D Remote
Alarm Distress Box
with printer
Internally accessed,
remove top cover
1 A mT
TT-3608A Hard Copy
Printer
Internally accessed,
remove top cover
1.5A mT.
TT-3608G Remote
Printer Unit
Internally accessed,
remove top cover
1 A mT
TT-3680B Power
Supply (200 Watt)
Internally accessed,
remove top cover.
4 A mT
3 x 16A T
5 x 10A T
Table 12 Capsat System Fuses
The TT-3680B Power Supply may blow an internal fuse in case you
power up the entire Integrated System with all DC units turned
on. It is therefore recommended to power up the DC units one by
one.
3.2
Compass Safe Distance
The compass safe distance of the individual devices in the TT-
3000C Maritime Capsat system has been measured in accordance
with the standards specified in ISO/R 694, Method B. The safe
distances found are: