TT-3042C Remote Alarm/Distress Box (optional)
TT-3042C Remote Alarm/Distress Box (optional)
TT-3042C Remote Alarm/Distress Box (optional)
TT-3042C Remote Alarm/Distress Box (optional)
System Installation
System Installation
System Installation
System Installation
25-Jul-00
25-Jul-00
25-Jul-00
25-Jul-00
Page
Page
Page
Page 3-43
3-43
3-43
3-43
The light intensity of the Power indicator can be adjusted by a
knob below it.
J1 PIN
J1 PIN
J1 PIN
J1 PIN
TT
TT
TT
TT-3042C Description
-3042C Description
-3042C Description
-3042C Description
X4 PIN
X4 PIN
X4 PIN
X4 PIN
Satellite Communica-
tion Unit
1
+ 7.5 - 12 Volt
5
+9Volt for ext. devices
2
GND + Safety GND †
6
GND
3
Distress button-lamp
1
In/Out 0
4
Buzzer/Buzzer knob
2
In/Out 1
5
To Distress Relay
3
In/Out 2
6
To Fault Relay
4
In/Out 3
7
Distress button
14
In 4
8
GND
15
In 5
9
Distress Relay contact pole 1
10
Distress Relay contact pole 2
11
Fault Relay contact pole 1
12
Fault Relay contact pole 2
Table 27 TT-3042C and Satellite Communication Unit inter-
connection
Note †:
Cable screen included
The cable used for the connection between the TT-3042C Remote
Alarm/Distress Box and the TT-3020C Transceiver, has to be cho-
sen in accordance with the specifications in Table 28 TT-3042C
Technical Specifications.
The Remote Alarm/Distress Box is in full compliance with the In-
marsat CN114, IEC 945 and Wheel Mark specifications.