TT-3042D Remote Alarm / Printer Unit
TT-3042D Remote Alarm / Printer Unit
TT-3042D Remote Alarm / Printer Unit
TT-3042D Remote Alarm / Printer Unit
System Installation
System Installation
System Installation
System Installation
25-Jul-00
25-Jul-00
25-Jul-00
25-Jul-00
Page
Page
Page
Page 3-51
3-51
3-51
3-51
Position
Setting
Fact.
Address
1-3
off,off,off:
1
1
off,off,on:
2
off,on,off:
3
off,on,on:
4
on,off,off:
5
on,off,on:
6
on,on,off:
7
on,on,on:
81
Printing Direction
4
on:
Reverse
off
off:
Normal
Sounder Timeout
5
on
10 sec. Timeout
off
no timeout
off
NMEA/Aux.Port
6
on:
NMEA 01832
NMEA
off:
Serial data3
Dot Energy
7
on:
High
High
off:
Normal
Printing Width
8
on:
40 Chars per line
80
off:
80 Chars per line
Table 29 TT-3042D DIP switch settings.
1 When this address is selected the TT-3042D is configured as local
printer. This address should not be used if a TT-3608A Hard Copy Printer
is connected to the TT-3020C transceiver.
2 Jumper W2 and W9 should be in position 1-2 (low) in Rx mode to
achieve optical isolation, else position 2-3 (high).
3 Jumper W2 and W9 must be in position 2-3 (high).