Chapter 3: Service & maintenance
54
Troubleshooting guide
Replacing the fuse in the power connector
One fuse is installed in the power connector. If the fuse is blown, do as
follows:
1. Track down why the fuse was blown and solve the problem.
2. Take out the old fuse.
3. Insert the new fuse. The fuse rating is 10 A T.
WARNING:
POWER
SUPPLY
LOST
CONTACT
Power supply
status cannot
be
monitored.
In Setup, Power Supply, set Monitor to disabled.
You can only monitor the power supply if the radio
is powered by a TT-6081A Power Supply Unit and