THRUSH AIRCRAFT, INC – MODEL S2R-R1340
AIRCRAFT MAINTENANCE MANUAL
Effective: 01/01/08
9-5
* NOTE *
Excessive uncured adhesive
can be cleaned up with ketone
type solvents. (When using
solvents, extinguish all
ignition sources and follow
the manufacturer’s directions
and precautions for use and
handling such materials.)
Application of adhesive to
substrates should be made
within seventy-five minutes
after mixing. Working life is
eighty minutes. Higher
temperatures will reduce
these times.
Allow 24 hours for sealer to cure before
putting airplane back into service.
Reinstall tubes, controls and cables and
pump. Fill hopper and check for leaks.
Water should be allowed to stay in
hopper for a minimum of two hours with
no leaks.
SPRAY DISPERSAL SYSTEM
Ref. Figure 9-4
The standard spray dispersal system of
the S2R-R1340 consists of the hopper,
the pressure loading valve and tube, the
gatebox, the spray pump, recirculation
valve, delivery plumbing, and the nozzle
equipped spray boom.
Figure 9-3: Liquid Dispersal Equipment
DISPERSAL SYSTEM MAINTENANCE
In conjunction with the manufacturer's
instructions for maintenance of the spray
pump, it is recommended that at the 100
hour inspections the following be
accomplished:
A. Inspect the hopper baffles for
security and condition.