USERS MANUAL AURORA SERIES
DONGGUAN THUNDER LASER EQUIPMENT CO.,LTD
Shatian Town, Shatian Dadao, Mintian
Tel :(86)769 826653
Dongguan City, Guangdong Province, China
49
Pic4
(
3
)
Choose correct COM port and click connect, then set the screw pitch as 5, Pulse count as 5000.
Speed as 1(divided into 10 gears, 1 fastest, 10 slowest, 1-10 decreasing speed), then click Send,
successfully set window will be showed. And enter the focal length according to the recommended form.
Focal Length for different lens(for reference only)
F-160
F-210
F-290
20WATT
Focus length range
50WATT
P:30%, S:100mm/s,
PW:100ns
P:30%, S:100mm/s,
PW:100ns
Focus length range
215—217mm
393-395mm
20 WATT(MOPA)
P:30%, S:100mm/s,
PW:100ns
P:30%, S:100mm/s,
PW:100ns
Focus length range
215—217mm
393.5—395.5mm