56
Pic4
(
3
)
Choose correct COM port and click connect, then set the screw pitch as 5, Pulse count as 5000.
Speed as 2(divided into 9 gears, 1 fastest, 9 slowest, 1-9 decreasing speed), then click Send,
successfully set window will be showed. And enter the focal length according to the recommended form.
Focal Length for different lens(for reference only)
F-160
F-210
F-290
20WATT
Focus length range
50WATT
P:30%, S:100mm/s,
PW:100ns
P:30%, S:100mm/s,
PW:100ns
Focus length range
215—217mm
393-395mm
20 WATT(MOPA)
P:30%, S:100mm/s,
PW:100ns
P:30%, S:100mm/s,
PW:100ns
Focus length range
215—217mm
393.5—395.5mm