background image

5

Specifications

SPECIFICATIONS

MODEL

TDR15005

TDR15006

TDR15007

TYPE

Monocrystalline

Monocrystalline

Monocrystalline

MAX POWER

80W (2x40W)

160W (2x80W)

240W(3x80W)

OPEN CIRCUIT VOLTAGE

23.9V

22.5V

22.5V

SHORT CIRCUIT CURRENT

4.39A

9.46A

14.2A

MAX POWER VOLTAGE

20V

18V

18V

MAX POWER CURRENT

4A

8.89A

13.3A

DIMENSIONS (CLOSED)

675mm(L) x 460mm(W) x 70mm(D)

780mm(L) x 675mm(W) x 70mm(D)

780mm(L) x 675mm(W) x 105mm(D)

DIMENSIONS (OPEN)

1350mm(L) x 460mm(W) x 35mm(D)

1350mm(L) x 780mm(W) x 35mm(D)

2340mm(L) x 675mm(W) x 35mm(D)

OPERATING TEMP

-40° to 85°C

-40° to 85°C

-40° to 85°C

WEIGHT

8.2Kg

18.5Kg

20.5Kg

SOLAR PANEL REGULATOR 
TYPE

PWM

RATED VOLTAGE

12VDC/24VDC

RATED CURRENT

7A-20A

MAX INPUT VOLTAGE

25V

OPERATING VOLTAGE

8V (Regulator will not recognise a battery lower than 8V)

OPERATING TEMPERATURE

-20°C to 60°C

RECOMMENDED BATTERIES (NOT INCLUDED)
TYPE

12V (60Ah - 100Ah Lead Acid or GEL type)

Summary of Contents for TDR15005

Page 1: ...your personal safety read understand and follow the information provided in this instruction manual on the solar panel CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER MONOCRYSTALLINE FOLDING SOLAR P...

Page 2: ...Benefits 4 Components 5 Specifications 6 Installation and Connections 7 Safety Precautions 8 Choosing the Correct System 9 Troubleshooting Guide 10 Typical Battery Connections 11 Warranty Terms Condit...

Page 3: ...steners Panels are fitted with a heavy duty handle allowing for easy handling and removal from the protective carry bag Two clip type safety fasteners lock the panel shut during transportation Conveni...

Page 4: ...nels with heavy duty anodized aluminium frame 2 Heavy duty ABS handle 3 Heavy duty steel safety fasteners 4 Heavy duty aluminium fold support legs 5 Solar panel junction box 6 10m cable 7 Automatic SM...

Page 5: ...60mm W x 70mm D 780mm L x 675mm W x 70mm D 780mm L x 675mm W x 105mm D DIMENSIONS OPEN 1350mm L x 460mm W x 35mm D 1350mm L x 780mm W x 35mm D 2340mm L x 675mm W x 35mm D OPERATING TEMP 40 to 85 C 40...

Page 6: ...onnect the other supplied leads to the battery outputs Step Four Connect to the battery Connect the battery clamp extension to the panels via the Anderson style plug Be sure to connect to the correct...

Page 7: ...causing personal injury or a fire hazard 10 This unit is not intended for use by small children without adult supervision 11 Always avoid charging old damaged overly discharged or defective batteries...

Page 8: ...efinitely as it will fully charge the battery each day This is only a guideline as many factors can influence the amount of charge for example less sunlight hours during winter overcast days etc will...

Page 9: ...ttery are free from damage and connected correctly Check the battery voltage If the battery voltage is less than 8V the controller will not work Check the fuse The fuse will typically be blown for the...

Page 10: ...10 TYPICAL BATTERY CONNECTIONS Normal connection Parallel connection Typical Battery Connections Load Chassis ground 12V Load Chassis ground 12V 12V 12V CORRECT CORRECT...

Page 11: ...r or replace the unit This warranty does not apply to failure or damage to a Thunder product caused by incorrect or faulty fitment accidental or intentional damage failure of other products incorrect...