A. COMPLETION CHECKLIST
The following features must be verifi ed as operational
before the stair lift can be released for use:
Upper and lower limits:
Verify the lift stops
automatically at the top and bottom of the
track.
Final limits:
Verify the lift is inoperable in
both directions when each fi nal limit switch
is pressed.
Running Clearance:
Verify the lift clears all
obstructions.
Track Mounting Brackets:
Verify all track
mounting brackets are securely attached to
the stair treads, the track and at the pivot
points.
Track Splice:
Verify track joints are smooth
and free of burrs and gaps.
Gear Rack:
Verify the gear rack is
suffi ciently lubricated.
Track End Covers:
Verify the track end
covers are securely fastened to the track.
Track:
Verify the inside of the track is free
of foreign objects.
Chassis Rollers:
Verify the chassis roller
axles have been lubricated.
Footrest:
Verify the footrest clears all stair
nosings.
Verify the lift stops when the footrest
runs into an obstruction.
Verify the footrest folds up and stays
in the up position.
Verify the unit does not beep when it
stops at the upper and lower limits.
The unit will beep if stopped and not
on the charging strip