18
VI. SERVICE INFORMATION
A. GENERAL
SPECIFICATIONS
Rated Load:
375 lbs. (170 kg)
Speed:
18-25 fpm (dependant on angle of install
and load)
Travel:
32’ max. (track length)
Power Supply:
Dedicated* 115VAC, 60 Hz, 3-wire
grounded outlet
Incline Limits:
25° to 45°
ETL Listed when properly installed
B. STANDARD
EQUIPMENT
Drive System:
Rack and pinion
Motor:
.5 hp, 24 VDC
Motor Controller:
SoftStart/SoftStop
Brake:
Self locking worm gear
Seat:
• Standard - 18” wide fi xed seat with two fi xed
arms OR
• Select - 18” wide fi xed, upholstered seat with
OR
• Excel - 19” wide folding seat with two fixed
arms
• Seat belt
• 70° locking swivel at upper and lower landings
Controls:
Low voltage up-down hand-held control on
* ASME A18.1a / NEC Requirement
Notes:
•
The BOS model stair lifts are battery powered.
Two
12V batteries are wired in series to provide 24V to
the control system. The batteries are charged by
a 33VDC power supply plugged into the 115 VAC
outlet. The batteries are charged only when the
lift is parked at the upper or lower landing.
•
The call/send controls (transmitters) use infrared
signals.
There are two infrared sensors located on
the chassis access cover. There is a combination
of 4 different frequencies the transmitters can be
set to (both transmitters must be set to the same
frequency).
•
There is a half second delay after a control button
is pressed before the lift starts to move. After the
lift stops, the up/down controls are disabled for 3
seconds.
upper and lower
stops
upper and lower fi nal limit
charge spring
unit and two wireless remote controls
Safety Devices:
Footrest obstruction sensor
Swivel seat cut-off switch
Final limits
Warranty:
Five years on drive train (motor and gear)
Two years on all component parts
Summary of Contents for Citia BOS