2007.03.07
Flow2 stairlift
Tab 04: Install, adjust and release
www.ThyssenKruppAccessibility.nl
17
Assembly
4. Move the joystick in the control unit, the red LED flashes. Depending on the type of RF
equipment, the following message appears in the display:
Armrest control (ui).
Call and park (CP0).
Repeater (rEP).
Go to Section 3.4.2 if the red LED does not flash.
5. When registering a call and park unit, for example, at step 4 'CP0' in the display indicates that
the drive unit gives the RF equipment code '0' for further programming. If this does not match
the code you set yourself, go to step 7.
6. If the code does not match, the last digit in the display must be set so that it does match with
the [I] and [D] buttons. The [I] button increases the digit, going from '0' to '8' and then 'Att' for
the attendant control unit. The number is decreased with the [D] button.
7. Press the [E] button for 2 seconds. Registration is now carried out. The display now shows '7'
and the flashing red LED on the control unit goes out.
8. Check that the green LED lights when the control is operated on the control unit. This indicates
that the RF equipment has been programmed.
9. Carry out steps 2 to 9 for each control unit.
3.4.2
Re-registering a control unit
This section can be skipped when the control units have been registered without any problems.
If the red LED does not flash during registration when the joystick on the control unit is moved, there
is a good chance that it has already been registered. This can be undone by carrying out the
following actions.
1. Push the joystick on the control unit in a little
2. Move the joystick to the left until the LED lights green for a few
seconds and then release it.
3. After a few seconds the LED goes out: then move the joystick
to the right until the LED flashes red.
4. Go back to the previous section and continue with step 5.
Fig. 3-14 Re-registering a control
unit
1