MEASURES, LOGIC STATES AND COUNTERS
System diagnostic
OK/NOT OK
Device diagnostic
OK/NOT OK
Program diagnostic
OK/NOT OK
Data-base boot
OK/NOT OK
Data-base runtime
OK/NOT OK
DSP boot
OK/NOT OK
DSP run-time
OK/NOT OK
Memory boot
OK/NOT OK
Memory run-time
OK/NOT OK
Data Bus heavy
OK/NOT OK
PLC boot
OK/NOT OK
PLC run-time
OK/NOT OK
Protection I/O assigned verify startup
OK/NOT OK
Protection I/O assigned verify run-time major
OK/NOT OK
Total protection I/O assigned not-matching
0
Protection I/O assigned not-matching
PLC I/O assigned not-matching
OK/NOT OK
PLC I/O assigned not-matching run-time major
OK/NOT
OK
Total PLC I/O assigned not-matching
0
PLC I/O assigned not-matching
When a higher level anomaly is recognized
all protective functions are disabled
and the output relays
switch in no-trip state:
rest state if the output relay are set in
De-energized
mode
(contacts as shown in the diagrams)
active state if the output relay are set in
Energized
mode (opposite to what is shown in the dia-
grams).
The connections of the trip and diagnostic relays must be performed according to the application:
when the output relay must be normally energized and the circuit breaker must be open in case of
failure of the protection system, the self-test function must be enabled and assigned to the normally
energized relay selected for tripping.
The diagnostic alarms can be allocated to an output relay; for this purpose the
Self-test relay
pa-
rameter can be set inside the
Set \ Self-test Relay
submenu.
Pilot wire diagnostic
Detailed diagnostic information about the pilot wire are available.
(
Read \ Pilot wire diagnostic
).
BLIN1 pilot wire breaking diagnostic state
ON/OFF
Pilot wire BLIN1 shorted
ON/OFF
Selective Block - BLOCK2
The input and output state concerning the selective block are available (
Read \ Selective block-
BLOCK2
).
Block2 input
Phase protections input selective block state
BLK2IN-Iph
ON/OFF
Ground protections input selective block state
BLK2IN-IE ON/OFF
tB-Iph/IE Elapsed state
tB timeout
ON/OFF
Block2 output
Starting state of phase protections enabled
for external selective block on output
ST-Iph-BLK2
ON/OFF
Starting state of ground protections enabled
for external selective block on output
ST-IE-BLK2
ON/OFF
Phase protections output
selective block state
BLK2-OUT-Iph ON/OFF
Ground protections
output selective block state
BLK2-OUT-IE
ON/OFF
Phase and ground protections
output selective block state
BLK2-OUT-Iph/IE
ON/OFF
Fault recording - SFR
Recording is triggered by one or more causes (up to 8 simultaneous):
Fault counter
Date and time
Fault cause
Maximum current between
I
L1Lrms
-
I
L2Lrms
-
I
L3Lrms
I
LmaxL-rms-r
Phase RMS currents side L
I
L1Lr
,
I
L 2Lr
,
I
L 3Lr
Phase RMS currents side H
I
L1Hr
,
I
L 2Hr
,
I
L 3Hr
Phase voltages
U
L1r
,
U
L 2r
,
U
L 3r
Phase-to-phase voltages
U
12r
,
U
2 3r
,
U
31r
Residual current side 1
I
E1r
Calculated residual current side L
I
ECLr
Residual current side 2
I
E2r
Calculated residual current side H
I
ECHr
Stabilization current side H
I
ESHr
Residual voltage
U
Er
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
—
•
•
—
•
•
•
•
•
•
•
•
•
—