2. Indicator wires are discon-
nected
1. Disconnect power before cleaning and unplugging the power plug.
2. After the pot is fully cooled, empty food, water or oil in the pot to avoid scalding. In order
to ensure the food is fresh, clean oil should be used for each frying and boiling.
3. After the pot fully cools dowm, a clean cloth can be used to clean the pot body; do not
use a steel wool and other rough objects to clean the pot body. If it would be stored for a
long time, it should be cleaned with a detergent.
4.Do not immerse the entire product in water to avoid the risk of electric shock or malfunc-
tion.
5. After the pot is cleaned, it should be stored at a dry place after it is dried.
6. Any other servicing should be performed by an authorized service representative .
Model:AMR50-220 Rated voltage:120V~ Rated frequency:60Hz Rated frequency:1360W
Chapter 4 Care and Maintenance
Chapter 5 Safety Indicators of Product
Chapter 6 Failure Analysis and Troubleshooting
Electrical Schematic Diagram
Fault phenomenon
Causes
Solutions
ng indicator is
off
Pot body is
not hot
Pot body is
hot
1. Power line is not connect-
ed
Check the plug socket and
the power line lead are
intact, and plug it in place.
Send to the designated
after-sales service depart-
ment for maintenance.
Send to the designated
after-sales service depart-
ment for maintenance.
Thermostat is damaged
Fuse is damaged
Thermostat is damaged
Heating indicator is always
on
Automatic temperature limit
is not available
2. Internal wires are discon-
nected
1. Indicators are damaged
Temperature regulator
Temperature controller
Fuse protector
Indicat
or
Heating unit
7
6