 User Manual- Smart Seal Rev 1.0

Summary of Contents for SmartSeal TPS-BH-SE

Page 1: ...User Manual Temperature Sensor System SmartSeal...

Page 2: ...ft Seal Sensor 5 Powering 6 Operating 6 Operating States Normal State 7 Error Indications 9 Troubleshooting 10 Causes of Alerts 9 Self Test Function 9 System Overview 2 Functional Overview 2 System Co...

Page 3: ...It is also designed to operate on non NMEA 2000 equipped vessels as well on vessels with certain other networks via a converter e g NMEA 01830 Functional Overview The SmartSeal System is comprised of...

Page 4: ...are both visually and physically accessible Each MCU has two types of connectors on the bottom of its enclosure The first is used to connect the shaft seal sensor neutral safety switch and optional r...

Page 5: ...ain Control Unit and a panel mount design for installing into Consoles or Helm Stations The RMU s front panel display will have the same LED indicators and alarm speaker as found on the Main Control U...

Page 6: ...g Units to the Main control Unit Sensor Mounted On Shaft Seal Injection Fitting Sensor and Clamp on Fitting System Components Shaft Seal Sensor Connected to the Main Control Unit The Shaft Seal Sensor...

Page 7: ...ure Sensor is an autonomous system It continuously monitors shaft seal temperature s and reports results as visual and audible indications on the Main and Remote unit front panels It also broadcasts s...

Page 8: ...g condition Normal Operation Normal state is indicated by the Green LED s being illuminated when the engines are running This indicates that the system is operating with the shaft seal temperature bel...

Page 9: ...ith Alarm Siren Sound indicate CRITICAL ALERT condition PORT STBD NORMAL CRITICAL WARNING SILENCE Temperature Sensor System SmartSeal Critical Alert State A Critical Alert is indicated by the Red LED...

Page 10: ...ndicating all internal self tests have passed and the unit is operating correctly In addition the Main Control Unit will beep one or two times indicating it is a single or twin engine unit The Remote...

Page 11: ...on is due to a failure detected in the Main control unit self test which occurs on each power up Other internal issues could cause the self test to fail In this case please contact Technical Support f...

Page 12: ...ll Free Phone 800 420 0949 General Phone 954 420 0949 General Fax 954 420 5234 Order Fax 954 420 0945 WWW TIDESMARINE COM TIDESMARINE innovative products for the marine industry 2018 Tides Marine All...