Pag. 13/15
0CAR6IN019124_Manual_GLH110_Rev_0.3
Hydraulic Plant 11 (ConF = 11)
Name
Symb
ol
Pins
Fireplace Pump
P1
3 – 4
PWM1
19 - 16 o 14
Diverter Valve
P2
5 – 6 – 7
Boiler Integration
P3
8 – 9 – 10
Heating Pump
P4
11 – 12
PWM2
20 - 16 o 14
Fireplace Probe
S1
13 – 14
Flow Switch
S2
15 – 16
Probe/Ambient Thermostat
Pressure Sensor
S3
16 – 17 – 18
7.11.1 Parameters
Cod. Led
Description
U.
Min. Def. Max
A01
Fireplace Pump minimum temp. Thermostat
°C
20
35
90
A02
Thermostat Diverter Valve
°C
20
45
90
A03
Boiler Integration Thermostat
°C
20
45
90
A04
Heating Pump Thermostat
°C
20
45
90
b01
Ambient Probe Thermostat
°C
5
20
50
7.11.2 Operating Principle
S1
Checks
Management
P1
P4
S1< 5° [
A06
]
Deicing
ON
OFF
5° <S1< 35°
A06 <S1< A01
Fireplace OFF
OFF
OFF
30° <S1< 45°
A01 <S1< A07
Recirculation
ON
OFF
45° <S1< 80°
A02 <S1< A07
S2 = Open
e
Shower
OFF
Heating
ON
ON
S2 = Closed
o
Shower
ON
Sanitary (DHW)
OFF
OFF
S1> 80° [
A07
]
Safety
ON
ON
S1> 45° [
A02
]
Sanitary (DHW)
ON
P2
S1> 45° [
A03
]
Integration
9 - 10 OPEN
OFF
P3
Hydraulic Plant 12 (ConF = 12)
Name
Symb
ol
Pins
Fireplace Pump
P1
3 – 4
PWM1
19 - 16 o 14
Diverter Valve
P2
5 – 6 – 7
Boiler Integration
P3
8 – 9 – 10
Heating Pump
P4
11 – 12
PWM2
20 - 16 o 14
Fireplace Probe
S1
13 – 14
Flow Switch
S2
15 – 16
Probe/Ambient Thermostat
Pressure Sensor
S3
16 – 17 – 18
7.12.1 Parameters
Cod. Led
Description
U.
Min. Def. Max
A01
Fireplace Pump minimum temp. Thermostat
°C
20
35
90
A02
Thermostat Diverter Valve
°C
20
45
90
A03
Boiler Integration Thermostat
°C
20
45
90
A04
Heating Pump Thermostat
°C
20
45
90
b01
Ambient Probe Thermostat
°C
5
20
50
7.12.2 Operating Principle
S1
Checks
Management
P1
P4
S1< 5° [
A06
]
Deicing
ON
OFF
5° <S1< 35°
A06 <S1< A01
Fireplace OFF
OFF
OFF
30° <S1< 45°
A01 <S1< A07
Recirculation
ON
OFF
45° <S1< 80°
A02 <S1< A07
S2 = Open
e
Shower
OFF
Heating
ON
ON
S2 = Closed
o
Shower
ON
Sanitary (DHW)
ON
OFF
S1> 80° [
A07
]
Safety
ON
ON
S1> 45° [
A02
]
Sanitary (DHW)
ON
P2
S1> 45° [
A03
]
Integration
9 - 10 OPEN
OFF
P3