Pag. 15/15
0CAR6IN019124_Manual_GLH110_Rev_0.3
Hydraulic Plant 15 (ConF = 15)
Name
Symb
ol
Pins
Fireplace Pump
P1
3 - 4
PWM1
19 - 16 o 14
Service
P2
5 – 6 – 7
Boiler Integration
P3
8 – 9 – 10
Heating Pump
P4
11 - 12
PWM2
20 - 16 o 14
Fireplace Probe
S1
13 – 14
Buffer Probe Basso
S2
15 – 16
Buffer Probe Alto
S3
16 - 17
7.15.1 Parameters
Cod.
Led
Description
U.
Min. Def. Max
A01
Minimum temp. Pump Thermostat
°C
20
40
90
A09
Service Thermostat
°C
20
50
90
A19
Thermostat Integration on High Buffer Tank
°C
20
45
90
A17
Heating Pump Thermostat on High Buffer Tank
°C
20
45
90
d01
+
Differential Thermostat
Δ
(S1-S3)
°C
2
5
20
7.15.2 Operating Principle
S1
S3
Δ (S1-S3) Management
P1
S1< 5° [
A06
]
Deicing
ON
5° <S1< 40°
A06 <S1< A01
Fireplace OFF
OFF
S1> 40°
S1> A01
Δ< 5° [
d01
]
OFF
Δ> 5° [
d01
]
Buffer Loading
ON
S1> 75° [
A05
]
See Par. 5.11
Air Damper
OFF
P2
S1> 45° [
A09
]
See Par. 5.10
Service
ON
S3> 45° [
A19
]
Integration
(9 - 10 Open)
OFF
P3
S3> 45° [
A17
]
Heating
ON
P4
* Se P06=3
Hydraulic Plant 16 (ConF = 16)
Name
Symb
ol
Pins
Fireplace Pump
P1
3 - 4
PWM1
19 - 16 o 14
Valve
P2
5 – 6 – 7
Boiler Integration
P3
8 – 9 – 10
Heating Pump
P4
11 - 12
PWM2
20 - 16 o 14
Fireplace Probe
S1
13 – 14
Buffer Probe Basso
S2
15 – 16
Buffer Probe Alto
S3
16 - 17
7.16.1 Parameters
Cod.
Led
Description
U.
Min. Def. Max
A01
Minimum temp. Pump Thermostat
°C
20
40
90
A24
Thermostat Valve for Sanitary (DHW) Priority
°C
20
70
90
A19
Thermostat Integration on High Buffer Tank
°C
20
45
90
A17
Heating Pump Thermostat on High Buffer Tank
°C
20
45
90
d01
+
Differential Thermostat
Δ
(S1-S3 e S1-S2)
°C
2
5
20
7.16.2 Operating Principle
S1
S3
Δ (S1-S3) Δ (S1-S2) Management
P1
S1< 5° [
A06
]
Deicing
ON
5° <S1< 40°
A06 <S1< A01
Fireplace OFF
OFF
S1> 40°
S1> A01
S3< 70°
S3< A24
Δ< 5° [
d01
]
OFF
Δ> 5° [
d01
]
High Buffer
Loading
ON
S1> 40°
S1> A01
S3> 70°
S3> A24
Δ< 5° [
d01
]
OFF
Δ> 5° [
d01
]
Low Buffer
Loading
ON
S3> 70°
S3> A24
Low Buffer
Loading
ON
P2
S3> 45° [
A19
]
Integration
(9 - 10 Open)
OFF
P3
S3> 45° [
A17
]
Heating
ON
P4