Pag. 2/15
0CAR6IN019124_Manual_GLH110_Rev_0.3
4.
Control Panel: USE AND FUNCTIONS
ON/OFF
Exit the Menu
Gr
ill
Service
Shutter Manual Start
K1
K3
Scroll/Increase
Pump1 Test
Probes Menu
Enter User Menu
SET
Shower Key
K2
K4
Scroll/Decrease
Pump2 Test
Probes Menu
Fig. 3 Main Screen
S1 Probe Temperature
S1 Probe Displayed
P1 Output Activated
S2 Probe Displayed
P2 Output Activated
S3 Probe Displayed
Fashing: Ambient Thermostat open
P3 Output Activated
ON:
Flow Switch Closed
Fashing:
Shower Function Activated
P4 Output Activated
5.
FUNCTIONALITIES
IGNITION/EXTINGUISHING
Controller Ignition/Extinguishing is perforemd by applying prolongued pressure to
K1
key
OFF-mode is displayed by
K1
key being turned-on
When the controller is turned on, the following messages will appear
o
Product Code
t002
o
Product Revision
r 0.1
o
Configuration
CF01
PROBE DISPLAY
The display shows the correct temperature sensor value
S1
(
S1
led is lit up).
To enter the probe menu press either
K4
or
K3
, the temperature of Probe
S2
is displayed (
S2
Led flashes) or
S3
(
S3
Led
flashes)
By pressing
K3
or
K4
it is possible to scroll and check other connected probes
To exit the Menu press
K1
or wait 10 seconds
If the probe reading is below the minimum range of the sensor the message
Lo
appears
If the probe reading is above the maximum range of the sensor the message
Hi
appears
SAFETY FEATURE
When this function is activated;
P11
=
1
, it starts a heat disposing process to remove excess heat buildup of the fireplace
The management of the safety feature is expalined in the plumbing/hydraulic schematic drawing parapraphs
ALARM FUNCTION
If the temperature measured by
Sensor S1
exceeds the value of the thermostat alarm
A08
An audible and visual signal is activated (the temperature flashes on the Display)
SILENCE
Function: The audible signal can be turned off for 5 minutes by pressing any key. If the controller remains in
the alarm condition the audible signal will start again.
ANTIFREEZE FUNCTION
If the temperature measured by
Probe S1
falls below the value of the Antifreeze Thermostat
A06
The output for Pump
P1
is turned on for
t01
time
at intervals of
t02
time
The display will show the writing
ICE
PUMP P1 ANTISEIZE FUNCTION
If Pump
P1
remains inactive, also while OFF, for a time greater than Timer
t05
The output for Pump
P1
is turned-on for
t04
seconds
The display will show the writing
bLP
STANDBY FUNCTION
If the controller is
OFF
,
and in
ALARM
,
ANTIFREEZE
or
ANTISEIZE FUNCTION
of Pump
P1
The controller automatically turns itself
ON
At the end of
ANTIFREEZE
or
ANTISEIZE of Pump P1
functions, the controller will turn itself
OFF
.
Al the end of
ALARM
function the controller will remain
ON