Night Mode
This Menu allows you to set and enable the time slots for the night mode starting and
ending.
The time slots set is the same as the one shown in the Chrono Menu. For a programming
across midnight please set a time slot end to 23.59 and the following starting from 00.00
up to the time of your choice.
The night mode allow you to disable, inside the set time slots, the operation of the
following engines: Loading Engine (if
PA53
=1), Cleaning Engine (if
PA54
=1), Cleaning
Engine 2 (if
PA55
=1), Brazier Cleaning Engine (if
PA56
=1).
During the set times, the display shows the message
Night Mode
.
The menu is displayed only if at least one engine is disabled in
Night Mode
.
Remote
Keyboard**
(visible if
A52
>0)
Enable Thermostat
It allows to enable/disable the Room Thermostat.
Room Thermostat
Menu to modify the r emote keyboard Room Thermostat.
Load*
This menu allows loading manually the Auger. The system has to be in Off state to do
the loading. To close the Pressure switch contact, when the Auger starts to work, also
the Exhaust Fan is activated.
Cleaning Reset * This menu allows to reset the message of Function System Maintenance 2. It is visible
only if
T67
>0.
Chrono
(for LCD100 and
Menu to select the Chrono’s program modality and the timers of Ignition/Extinguishing of
the stove.